7 FUNCTION EXPLANATIONS
7.23

Gas post-flow (GMAW)

This controls the time during which shielding gas flows after the arc is extinguished.
Gas post-flow is set in the weld data setting menu under stop data.
7.24

Air post-flow (Gouging)

This controls the time during which air flows after the arc is extinguished.
Air post-flow is set in the weld data setting menu under stop data.
7.25

Crater filling

Crater filling makes a controlled reduction in the heat and size of the weld pool possible
when completing the weld. This makes it easier to avoid pores, thermal cracking and crater
formation in the weld joint.
Crate filling is set in the weld data setting menu under stop data.
7.26

Burnback time

Burnback time is a delay between the time when the wire starts to brake until the time when
the power source switches off the arc voltage. Too short burnback time results in a long wire
stickout after completion of welding, with a risk of the wire being caught in the solidifying weld
pool. Too long burnback time results in a shorter stickout, with increased risk of the arc
striking back to the contact tip.
Burnback time is set in the weld data setting menu under stop data.
7.27

Stop phases

Stop phases are mainly used for setting crater filling.
The following can be set for Stop phase1
ON
Time s
Time for welding in phase 1.
Arc voltage %
In percent of set voltage
Wire feed %
In percent of set wire feed
Welding current %
In percent of set welding current
Travel speed %
In percent of set travel speed
Stop phases are set in the weld data setting menu under stop data.
7.28

Dynamic regulation

The dynamic regulation function is developed for multiple electrode welding and alters the
characteristics of the power source. The characteristics of the power source are calculated
from the set wire data.
Dynamic regulation is selected in the weld data setting menu.
0460 949 474
The following can be set for Stop phase2
ON
Time s
Time for welding in phase 2.
Arc voltage %
In percent of set voltage
Wire feed %
In percent of set wire feed
Welding current %
In percent of set welding current
Travel speed %
In percent of set travel speed
- 28 -