Epson C Series Maintenance Manual page 650

6-axis robots
Hide thumbs Also See for C Series:
Table of Contents

Advertisement

C12 Maintenance 13. Replacing the LED Lamp
13. Replacing the LED Lamp
■ Do not connect or disconnect the motor connectors while the power to the robot
system is turned ON. Connecting or disconnecting the motor connectors with
the power ON is extremely hazardous and may result in serious bodily injury as
the Manipulator may move abnormally, and also may result in electric shock
and/or malfunction of the robot system.
■ To shut off power to the robot system, disconnect the power plug from the power
source. Be sure to connect the AC power cable to a power receptacle.
WARNING
DO NOT connect it directly to a factory power source.
■ Before performing any replacement procedure, turn OFF the Controller and
related equipment, and then disconnect the power plug from the power source.
Performing any replacement procedure with the power ON is extremely hazardous
and may result in electric shock and/or malfunction of the robot system.
Maintenance Part
Tool
630
Name
LED lamp
Cross-point screwdriver (#2)
LED lamp
Qty.
1668127
1
(Standard, Clean-room models)
1
For cross recessed head screws
C Series Maintenance Manual Rev.2