14. Remove the base cable bracket (C1) and the cable protection sheet.
Hexagon socket head cap bolts: 2-M3×6
15. Remove the Joint #1 timing belt.
16. Remove the battery from the battery box.
17. Disconnect the battery connector.
NOTE
Hold the board by hand and pull up the battery cable to disconnect
the connector.
18. Remove the plate to which the battery board is fixed.
Hexagon socket head cap bolts: 2-M4×10
C Series Maintenance Manual Rev.2
C12 Maintenance 4. Cable Unit
465