Leave out the other connector cables for a certain length, as shown in
the photo, in order to store them in the Arm #3.
7. Pass the Ethernet cable, X052/X062 cable, and ground wire
(green/yellow) from the Arm #3 side to the Arm #4 side.
First pass the braid tube from the Arm #4 side to the Arm #3 side.
Insert the connectors through the braid tube, as shown in the photo, and
fix the tube with the wire tie so that connectors are not to be pulled out.
Then, pull the braid tube from the Arm #4 side while pushing the cables
from the Arm #3 side to pass the cables through.
(See the photo.)
8. Pass the separated cable unit (Arm #4 side) from the Arm #4 to the Arm
#3.
Silicone tube is provided. Leave out the silicone tube on the Arm #4
side.
Pass the following cables through the silicone tube: Ethernet cable,
X052/X062 cable, and ground wire (green/yellow) that have been
passed from the Arm #3 side.
C Series Maintenance Manual Rev.2
C12 Maintenance 4. Cable Unit