C8-A701*B* (C8), C8-A901*B* (C8L)
Installation
Install the base cover to the Manipulator.
(S, C models)
Hexagon socket head cap bolts: 11-M4×10
Tightening Torque: 4.0 ± 0.2 N·m
NOTE
C8-A701*B* (C8), C8-A901*B* (C8L)
Installation
1.
model
(P
)
2.
NOTE
3.
NOTE
C Series Maintenance Manual Rev.2
Be careful not to get the cables caught between the cover and the Manipulator.
Install the spacers to the holes on the gasket.
(11 places)
Apply the liquid gasket to the base rear gasket.
Install the base rear gasket to the base cover.
(See the figure for gasket applying points)
Gasket
Applying
point (×11)
After applying the liquid gasket, leave the gasket until the liquid gasket becomes
solid and the gasket is fixed.
Install the base cover to the Manipulator.
Hexagon socket head cap bolts: 11-M4×10
Tightening torque: 4.0 ± 0.2 N·m
Be careful not to get the gasket and cables caught between the cover and the
Manipulator.
Replace the gasket if there are flaws or deteriorations.
C8 Maintenance 3. Covers
Spacer (×11)
Base rear gasket
Base cover