Epson C Series Maintenance Manual page 162

6-axis robots
Hide thumbs Also See for C Series:
Table of Contents

Advertisement

C4 Maintenance 10. Joint #6
11. Remove the wave generator from the shaft.
If the shaft has a bearing, remove it. The bearing will be used again. Be
careful not to lose it.
There is a washer between the nut and the wave generator.
Be careful not to lose it.
The parts are greased. Wipe grease on the parts while removing them.
Open-end wrench width for the shaft: 5.5 mm
Open-end wrench width for the nut: 8 mm
142
C Series Maintenance Manual Rev.2