Section E
76 - 8
Reconditioning (continued)
Jig Usage (continued)
10. Removal of correction jig
9803/6400
Hydraulics
Hydraulic Rams
After completion of the correction of the seal ring, remove
the jig in the following order.
1. Remove the press rod.
2. Remove the correction jig.
This completes the fitting and correction of the seal ring.