jcb JS200 Service Manual page 169

Hide thumbs Also See for JS200:
Table of Contents

Advertisement

Section C
8 - 2
Each item is changed with the Self Check Switches located
on the right hand side of the back-up switch.
There are four Self Check Switches
1. The CHANGE switch which is used to change to the
self-check mode.
2. PATTERN switch which changes from the service
check function to the setting function.
3. SELECT switch which moves from item to item.
4. RESET which locks the set values into the controller.
This set of four switches are usually covered so that the
operator cannot accidentally operate them.
Checking Methods
When the engine key is inserted and turned to the ON
position, the "STANDARD MODE" is displayed in the
Message display section, and S is displayed in the WORK
mode section and theTIME is displayed in the CLOCK
display.
When the CHANGE switch is pressed the Country and Model
designation is displayed:
0200 = JS200
0220 = JS240
9803/6400
Electrics
Self Test
*
ADJUST/CLOCK
H
M
Cover installation
screws x 2
Message
S : STANDARD MODE
WORK MODE
CLOCK
Message
CH : MN
WORK MODE
CLOCK
Self-check
MANUAL THROTTLE
BACK UP
Change
UP
DOWN
Select
Self-check
Change
Select
Self-check
Change
Pattern
MODE
Select
Reset
Self-check
Change
MODE
Section C
8 - 2
Pattern
Reset
Pattern
Reset
Issue 2*