jcb JS200 Service Manual page 197

Hide thumbs Also See for JS200:
Table of Contents

Advertisement

Section C
10 - 3
To read stored information on channel 3
1
Remove redundancy buttons cover.
2
Switch on the ignition.
3
Press the change button once.
4
Press the pattern button twice.
5
Set the working mode to H mode.
If the monitor now gives 3 beeps this is to indicate that
no faults have occurred and therefore no information
has been stored.
If the monitor does not give 3 beeps then one or more
faults have occurred and been stored.
6
Press the select button once.
7
The monitor will now display the first numerical fault
code.
Make a note of the numerical codes in the mode
screen clock screen and message window (refer this
to data sheet for channel 3).
Press the select button again, if a second fault has
been stored, the monitor will display the fault codes for
this fault.
If no second fault has been stored then the display will
return to the clock time and mode indication.
9803/6400
Electrics
CAPs II Diagnostic system
H
10.30
4
3
ADJUST/CLOCK
MANUAL THROTTLE
H
M
UP
DOWN
Cover installation
screws x 2
Self-check
Change
Pattern
Select
Reset
Self-check
Change
Pattern
Select
Reset
MODE
Self-check
Change
Pattern
Select
Reset
MODE
Section C
10 - 3
Self-check
BACK UP
Change
Pattern
Select
Reset
Self-check
Change
Pattern
Select
Reset
CH: 3
A296560
CH: 3
A296560
Issue 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Js210Js220Js240Js260

Table of Contents