Pressing SELECT changes the display as shown.
The fuel sensor resistance is shown in Ohms in the clock
display.
Pressing SELECT changes the display as shown.
A value of 0 to a maximum of 4.5 Volts will be displayed in
the clock display depending on the position of the throttle.
*
Pressing SELECT changes the display as shown.This
monitors transistor block output.
When TR is displayed, pressing the reset button once will
initiate the controller to test all the transistor block outputs 1
through 20. If a faulty output is detected it will stop at that
output number. Monitor will display "ELEC. PROBLEM"
(short circuits only).
To detect open circuits, select different services in turn and
check screen display:
e.g. '1' = closed circuit
'0' = open circuit
9803/6400
T
1
Free swing solenoid valve
R
2
2 stage MRV control solenoid valve
A
3
Low flow hydraulic circuit
N
4
Servo isolator solenoid valve
S
5
Slew shut off solenoid valve
I
6
Not used
S
C
T
7
Not used
O
O
8
Not used
R
N
9
Boom lower speed restriction solenoid valve
T
O
10 Not used
U
R
T
11 Slew lock solenoid valve
O
P
12 Max flow cut solenoid valve
L
U
13 Cushion solenoid valve
T
L
14 Not used
E
15 Not used
N
16 Negative control solenoid valve
U
R
M
B
17 Battery relay
E
18 Glow plug relay
R
19 Slew brake solenoid
S
20 2 speed travel solenoid valve
1 0 1
Block 3
Block 2
Electrics
Self Test
*
FUEL SENSOR RESISTANCE VALUE
Message
CH : FS
WORK MODE
CLOCK
THROTTLE VOLUME VOLTAGE
Message
CH : TV
WORK MODE
CLOCK
TRANSISTOR OUTPUT VOLTAGE
Message
CH : TR
WORK MODE
CLOCK
0 = Output off, 1 = Output on
Block 1
Section C
Self-check
MODE
Select
Self-check
MODE
Select
Self-check
MODE
Select
Block 1
Block 2
Block 3
8 - 4