ENGINE / COOLING / HVAC SYSTEM

CONDENSER REPLACEMENT

1. Remove the refrigerant from the A/C system.
WARNING
In the event of a leak, wear safety goggles. Escaping
refrigerant can cause severe injuries to eyes. In contact
with a flame, R-134a refrigerant gives a toxic gas.
2. Remove the left rear fender.
3. Disconnect the outlet hose
4. Disconnect the inlet tube
5. Cap and plug the tube and the condenser fittings
with the proper A/C caps and plugs.
6. Remove the two bolts
the way.
3.134
q
from the condenser.
w
from the condenser
e
and move the drier out of
7. Remove the two bolts
condenser.
t
8. Remove the bolt
9. Remove the condenser from the vehicle.
10. Installation: Reverse procedure. Tighten fasteners
to specification.
Upper Condenser Hose:
18 ft-lb (24 Nm)
Lower Condenser / Receiver-Drier Hose:
12 ft-lb (16 Nm)
Condenser Upper Mounting Bolt:
14 ft-lb (19 Nm)
Condenser Lower Mounting Bolts:
8 ft-lb (11 Nm)
11. Recharge A/C system.
9929399 R01 - 2018-2019 RANGER XP/ CREW 900/1000 Service Manual