8. Disconnect CPS (F), vehicle speed sensor (G), ECT
sensor (H) and transmission switch (I). Remove the
tie
straps
(J)
retaining
transmission.
9. Remove the vent line (K) from the transmission fitting.
10. Disconnect the transmission shift cable (L) by
removing the clip (M) and sliding the washer and shift
cable off the bellcrank.
11. Mark the location of the upper shift cable jam nut (N).
Loosen the lower jam nut (P) and remove the shift
cable assembly from the bracket (Q).
9929399 R01 - 2018-2019 RANGER XP/ CREW 900/1000 Service Manual
© Copyright Polaris Industries Inc.
12. Relieve pressure from the fuel rail. Disconnect the
the
harness
to
the
13. Using a 13mm socket and wrench, remove the
14. Using a long screwdriver, loosen both hose clamps
15. Use an overhead or portable hoist to support the
16. Using a 15 mm socket, remove the four bolts from the
fuel line at the fuel rail wrap the ends with a clean rag
to assure no dirt gets in the fuel system.
fastener (R) securing the bottom of the intake plenum
to the rear transmission mount.
(S) that retain the intake plenum runners to the
cylinder head intake adapters. Remove the intake
plenum and electronic throttle control as an
assembly.
transmission by securing a strap (T) through the rear
mount.
NOTICE
Place a spacer or support between the vehicle frame
and engine to hold the engine up in position while
removing the transmission to engine mounting bolts.
left side (U) and right side (V), securing the
transmission to the engine.
TRANSMISSION
6
6.9

Advertisement