Temperature / Pressure Chart - Polaris RANGER XP 900 2018-2019 Service Manual

Table of Contents

Advertisement

TEMPERATURE / PRESSURE CHART

TEMP °F
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
45
50
55
60
65
70
75
80
85
90
91
92
Evaporator
Pressures represent gas temperatures inside the coil, not the coil surface. For an estimate of the temperature of the air
coming off the coil add 8 - 10°F (-13 to -12°C) to the temperature on the chart.
Condenser
Temperatures are not ambient temperatures but condensing temperatures. Add 4.4° C (40° F) to the ambient
temperature to get the condensing temperature and then refer to the pressure chart to see appropriate pressure for
ambient temperature.
Example: Ambient Temperature = 90ºF
90ºF + 40ºF = 130ºF condenser temperature / 200 PSIG
Conditions and pressures will vary from system to system.
9929399 R01 - 2018-2019 RANGER XP/ CREW 900/1000 Service Manual
© Copyright Polaris Industries Inc.
PSIG
15.69
17.04
18.43
19.87
21.35
22.88
24.47
26.10
27.79
29.52
31.32
33.17
35.07
37.03
39.05
40.09
45.48
51.27
57.47
64.10
71.19
78.75
86.80
95.40
104.40
106.30
108.20
ENGINE / COOLING / HVAC SYSTEM
TEMP °F
93
94
95
100
102
104
106
108
110
112
114
116
118
120
122
124
126
128
130
135
140
145
150
155
160
165
170
PSIG
110.20
112.10
114.10
124.30
128.50
132.90
137.30
3
141.90
146.50
151.30
156.10
161.10
166.10
171.30
176.60
182.00
187.50
193.10
198.90
213.70
229.40
245.80
263.00
281.10
300.10
320.10
340.80
3.147