22. Install the oil sump cover (G) onto the crankcase.
23. Install the thirteen M6 and three M8 bolts that retain
the oil sump cover (H) to the crankcase.
9929399 R01 - 2018-2019 RANGER XP/ CREW 900/1000 Service Manual
© Copyright Polaris Industries Inc.
ENGINE / COOLING / HVAC SYSTEM
24. Torque the oil sump cover bolts in sequence to
specification. Repeat the sequence to verify final
torque.
TORQUE
Oil Sump Cover Bolts:
M6 Bolts: 9 lb-ft (12 Nm)
M8 Bolts: 26 lb-ft (35 Nm)
25. Reinstall the crankcase drain plug if previously
removed. Torque drain plug to specification.
TORQUE
Crankcase Drain Plug:
12 lb-ft (16 Nm)
26. Rotate the engine so the cylinder is facing up.
27. Reinstall the oil cooler (J), if previously removed.
Use new O-rings upon installation.