CESSNA
MODEL 208B 867 SHP
GARMIN G1000
SMOKE AND FIRE
CABIN FIRE
1. STBY ALT PWR Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . OFF
2. GENERATOR Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . TRIP
3. BATTERY Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OFF
•
Without electrical power all electrically operated
flight and engine indications, fuel boost pump,
EIS annunciators, WING FLAPS Handle and all
navigation and communications systems will be
inoperative.
•
All
standby
indicator and vacuum-driven standby attitude
indicator, will be operative.
4. Vents . . . . . . . . . . . . . . . . . . . . . . . . CLOSED (to avoid drafts)
a. Forward Side Air VENT Knobs . . . . . . . CLOSE (push in)
b. Overhead Air Vents . . . . . . . . . . . . . . . . . . . . . . . . CLOSE
c. VENT AIR Control Knobs . . . . . . . . . . . . . . . . . . . CLOSE
d. AIR CONDITIONING Switch (if installed) . . . . . . . . . . OFF
5. TEMP Control Knob . . . . . . . . . . . . . . . . . . . . . . . . . . CLOSED
6. BLEED AIR HEAT Switch . . . . . . . . . . . . . . . . . . . . . . . . . OFF
7. Fire Extinguisher . . . . . . . . . . . . . . . . . . . . . . . . . . . ACTIVATE
Occupants should use oxygen masks (if installed)
until
smoke
extinguisher within a closed cabin, ventilate the
cabin.
8. Land airplane as soon as possible to inspect for damage.
FAA APPROVED
208BPHCUS-00
EMERGENCY PROCEDURES
(Continued)
WARNING
instruments,
(rotate FULL counterclockwise)
WARNING
clears.
After
SECTION 3
including
torque
discharging
U.S.
an
3-21