CESSNA
MODEL 208B 867 SHP
GARMIN G1000
OPERATING LIMITATIONS
ON GROUND
MOST LIMITING OF THE FOLLOWING:
1. Do not exceed 105 amps as indicated by the GEN AMPS
indicator with engine power setting at 55 - 64% Ng.
2. Do not exceed 170 amps as indicated by the GEN AMPS
indicator with engine power settings at or above 65% Ng.
3. The maximum generator load listed below as a function Ng, air
conditioning and bleed air heat position.
MAXIMUM GENERATOR LOAD - GROUND OPERATIONS
AIR CONDITIONING - OFF,
BLEED AIR HEAT - ON or OFF
Ng
55%
60%
65%
FAA APPROVED
208BPHCUS-S8-00
SECTION 9 - SUPPLEMENTS
or
AIR CONDITIONING - ON,
BLEED AIR HEAT - OFF
AMPS
95
105
170
Figure S8-1
SUPPLEMENT 8
Ng
AMPS
55%
60%
65%
U.S.
50
105
170
S8-5