Hitachi DKC910I Installation Section page 179

Hide thumbs Also See for DKC910I:
Table of Contents

Advertisement

Hitachi Proprietary
Rev.1.1
INST(IN)14-01-40
START
(1)-0 Backup the current Config to the maintenance PC.
(1)-1 Check the DKC Serial Number and remember them for later use in step (11), "System Tuning" (SVP02-18-10).
(1)-2 Turn off the "POWER ON/OFF" switch on the HSNPANEL.
(1)-3 Make sure the breaker is off (DKU and DKC). (If it is "on", turn off the breaker after the SVP is shut down.)
(1)-4 If the PUBLIC (SNMP Web Console) or INTERNAL (other device) cables in the SVP are connected, disconnect them. Do
not disconnect other cables.
(2)
Turn on the breaker (DKU and DKC) and wait for the SVP ready to use.
(Donʼt turn on the "POWER ON/OFF" switch on the HSNPANEL.)
(3)
Set the SVP PS ON/OFF INH switch (SVP RAS SW #1) on the SSVP to ON (lower position).
When the Additional SVP is installed, set the SVP PS ON/OFF INH switch (SVP RAS SW #1) on the SSVP1 to ON (lower
position).
(SVP procedure)
(4)
Set TOD
(At this time, "Communication Error" may occur. You can ignore the error.)
(SVP procedure)
(5)
Execute the following procedures: (*6)
[Install micro-programs and configuration to the HD to the SVP]
step1: Connect to the SVP display from the Maintenance PC by the remote desktop.
step2: Prepare the media.
step3: Uninstall any additional software installed on the SVP such as Hitachi Remote Ops/C-Track and Anti-Virus client.
step4: Insert the media disk into the Maintenance PCʼs drive.
<Breaker: (INST(AD)11-01-20), SVP Shut Down: (SVP01-200)>
<Power ON Procedure of Storage system: (INST(GE)05-01-10)>
DKC910I
Copyright © 2019, 2021, Hitachi, Ltd.
(LOC04-50)
(LOC03-40)
(INST(IN)14-02-10)
(REP(RSVP)05-60)
[INST(IN)14-01-40]