Hitachi Proprietary
DKC910I
Rev.2
Copyright © 2019, 2021, Hitachi, Ltd.
INST(IN)00-00-00
INSTALLATION SECTION
[Installation Procedures]
[INST(IN)00-00-00]

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi DKC910I

  • Page 1 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)00-00-00 INSTALLATION SECTION [Installation Procedures] [INST(IN)00-00-00]...
  • Page 2: Table Of Contents

    Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)00-00-10 Contents 1. Procedures for Installing Storage System ..............INST(IN)01-01-10 2. Unpacking and Installing the Rack Frame ..............INST(IN)02-01-10 2.1 Unpacking the RKU Rack Frame ................. INST(IN)02-01-10 2.2 Size ........................INST(IN)02-02-10 2.3 Installation of RKU Rack and Side Cover...
  • Page 3 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)00-00-20 8.5 Attach the CHB port number labels ..............INST(IN)08-05-10 9. Connecting Cables ..................... INST(IN)09-01-10 9.1 Connecting Interface Cables ................INST(IN)09-01-50 9.1.1 Connecting Fibre Channel Cables ............... INST(IN)09-01-60 9.1.2 Connecting iSCSI Cables ................
  • Page 4: Procedures For Installing Storage System

    Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)01-01-10 1. Procedures for Installing Storage System 1. Procedures for installation on the rack frame In case of a new introduction or moving the Storage System, perform the installation after making sure of the following necessary works.
  • Page 5 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)01-01-20 2. Tools required The following tools are required for the installation. Table 1-1 Tools Required Division Tool name Specification Usage Tool Phillips screwdriver No.2 Fixing of Storage System Allen wrench No.3...
  • Page 6: Unpacking And Installing The Rack Frame

    “3. Installing Rails” and the following steps. NOTE : If you use rack frames other than Hitachi racks, note the following: “2.1 Unpacking the RKU • Replace the values of the depth and width described in Rack Frame”...
  • Page 7 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-01-20 Figure 2-1 RKU Rack Frame Packed Status  Crepe tape   Cotton tape  Polyethylene bag  Wooden cap   Moving direction  RKU rack frame Leveling bolt...
  • Page 8 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-01-30 2. Checking external appearance of the Storage System Check the external appearance of the rack frame for distortion or damage owing to the transport. Figure 2-2 External Appearance of Rack Frame...
  • Page 9 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-01-40 4. Installation Area/Maintenance Area and Earthquake-resistant Plan (1) Installation area (for one rack) and maintenance area Figure 2-3 shows installation and maintenance areas for the A-6516-RKU3 rack frame and a cut- out figure using a free access floor.
  • Page 10 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-01-41 When installing two or more RKU racks with them connected, calculate the total weight of the “(2) Calculation of total weight of storage storage system according to system”, and then calculate (a) and (b) by using the calculation formula shown in “(4) Installation area when installing...
  • Page 11 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-01-50 For example, the total weight of the storage system when two SBXs and one UBX are installed in the single CBX pair configuration is calculated as follows: RKU rack (213 kg) + DKC (75 kg 2) + HSNBX (15 kg 2) + SBX (96 kg 2) + UBX (216 kg)
  • Page 12 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-01-60 (3) Reference matrix of clearances between racks Values of the right and left side clearance (a) and the front and rear side clearance (b) that are illustrated in Figure 2-3 are shown by total weight of the storage system in the following tables.
  • Page 13 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-01-70 Table 2-3 Right and Left Side Clearance (a) for Floor Load Capacity of 2,940 Pa (300 kgf/m Total weight of storage system Right and left side clearance (a) (x) (unit: kg)
  • Page 14 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-01-80 Table 2-6 Right and Left Side Clearance (a) for Floor Load Capacity of 4,410 Pa (450 kgf/m Total weight of storage system Right and left side clearance (a) (x) (unit: kg)
  • Page 15 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-01-90 (4) Installation area when installing multiple RKU racks with them connected When connecting multiple racks, calculate the right and left side clearance (a) according to the formula shown below. Note that the minimum clearance of 200 mm must be secured to perform maintenance work even though the calculated value is smaller than 200 mm.
  • Page 16: Size

    Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-02-10 2.2 Size 1. Rack frame Figure 2-4 Rack Size Top view (Unit : mm) Front view Side view [INST(IN)02-02-10]...
  • Page 17: Installation Of Rku Rack And Side Cover

    Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-03-10 2.3 Installation of RKU Rack and Side Cover • Make sure that the equipment is moved by two or more persons. • Be sure to move the equipment by pushing it from the front face in the direction of movement.
  • Page 18 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-03-20 Moving the equipment forward with limited space When moving the equipment in the direction of the front of the rack frame, two persons must cooperate. One pulls the front face of the rack frame in the direction of the installation location and the other pushes the rear face of the rack frame with hands on the both ends of the rear door at the position that is more than 50mm far from the door lock holding side covers.
  • Page 19 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-03-30 Moving the equipment in a lateral direction When locating the equipment next to the equipment that was already installed, two persons must cooperate. One pulls the front face of the rack frame and the other holds the side face of the rack frame to move it.
  • Page 20 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-03-40 1. Confirmation of Rack Frames Installation Location (1) Confirm the Rack Frames installation location and the Side Covers installation position. (2) When the Side Covers are needed to remove, remove the Side Covers referring to Figure 2-15.
  • Page 21 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-03-50 2. Earthquake-resistant Plan Figure 2-9 shows a cross-sectional diagram of the floor of the A-6516-RKU3 rack frame. Refer to it for the earthquake-resistant plan. Figure 2-9 Cross-sectional View of Floor of A-6516-RKU3 Rack Frame 3.
  • Page 22 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-03-60 4. Installation of Rack Frames Prevent the overturning of the equipment when moving it: When moving the equipment, check that there are no obstacles or holes on the floor and make sure that the equipment is moved by two or more persons.
  • Page 23 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-03-70 (4) Ensure the clearance between the caster and the floor by approximately 2.5 mm when the height adjustment is performed. (One revolution of screw jack = 2.5 mm) Caution of Over-Turning/Jammed Connecting Bolts: Work carefully for the height adjustment.
  • Page 24 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-03-80 5. Connection of Rack Frames If you install multiple rack frames, connect them. If the connection work is not required, go to Step (1) Remove the two screws from the front side of the Rack Frames to be connected and then remove the two panels by moving them upward.
  • Page 25 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-03-90 (2) Connect the front of the rack frames with the two joint plates and the eight screws. Figure 2-13 Connection of Rack Frames (Front) Rack Frame Screw Joint Plate...
  • Page 26 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-03-100 (3) Connect the rear of the rack frames with the two joint plates and the eight screws. (4) Reinstall the two panels that is removed on the procedure a, and secure them with the two screws.
  • Page 27 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-03-110 6. Installation of Side Covers Paying attention to falls: Dropping a side cover may cause injury. When installing or removing the side cover, hold the cover firmly with both hands and be careful not to drop it on your feet.
  • Page 28 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-03-120 7. Attachment of FG cable (1) Remove the screw securing the FG cable for the rear door from the rack frame. (2) Attach the two FG cables for rack frame connection, and secure them with the two lock washers and the two screws while bundling the FG cable for the rear door with the one of the FG cables for rack frame connection.
  • Page 29 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)02-03-130 8. Removing the decoration panels (1 U) When the decoration panels have been attached, it is necessary to remove the decoration panel of installation position. (1) Pull the decorative panel toward you.
  • Page 30: Installing Rails

    Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-10 3. Installing Rails NOTE: Use the mounting holes of the rack that are level front to back and side to side when installing the rails so that installed equipment and options are horizontally positioned.
  • Page 31 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-20 Addresses within the rack frame are called (EIA) unit numbers. The addresses are given as 1, 2, 3, and so on counted from the bottom of the rack frame.
  • Page 32 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-30 Figure 3-3 Whole Layout of Diagram Addresses of installation positions :Area for installing the chassis [INST(IN)03-01-30]...
  • Page 33 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-40 1. Installing rails for Controller Chassis The rail install procedure is different depending on the hole shape (square or circular hole) on the rack. Check the holes on the rack before the installation work.
  • Page 34 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-50 NOTE : • There are the rail (R) and the rail (L). Check that with the marking on the rail. • These rails extend or shorten back and forth •...
  • Page 35 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-51 Figure 3-5 Installing Rails for Controller Chassis (without Stopper) Cage nut Unit boundary Rack frame (rear side) rack nut Unit boundary Unit boundary Unit boundary Unit boundary Rail (R)
  • Page 36 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-52 Figure 3-6 Installing Rails for Controller Chassis (with Stopper) Cage nut Unit boundary Rack frame (rear side) rack nut Unit boundary Unit boundary Unit boundary Stopper Unit boundary Rail (R)
  • Page 37 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-60 2. Installing rails for Drive Box (SBX/UBX) The rail install procedure is different depending on the hole shape (square or circular hole) on the rack. Check the holes on the rack before the installation work.
  • Page 38 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-70 NOTE: • The shape of the rail (R) and that of the rail (L) are the same. However, the place to attach the nut is different. When viewed from the front of the rack, the difference is as follows: Right side: The part that can be extended is the rear side.
  • Page 39 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-80 (6) Bring down two Clips on the front and rear edge of the rail. (7) Fit Positioning Pins  and  of the rail (two pins in total on the front and back edge) into holes on the right side of the rack at the position where you want to install the Drive Box.
  • Page 40 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-90 (9) Tighten the screw (SBB-RAIL) and the loop cable tie on the rear edge of the rail to fix the rail to the rack. The fixing position is the fourth hole from the bottom of the unit boundary line.
  • Page 41 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-100 NOTE: • Front rails have two types; (R) and (L). Check that with the marking on the rail. • These rails extend or shorten back and forth. (1) Open two clips on the front and back of the rail (R).
  • Page 42 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-110 (3) Loosen the four screws on the side of the rail (R) and adjust the rail (R) length. When the rack frame and the rail width do not match even if loosening the screws, remove the four screws, adjust the length, and then fix the rail with four screws again.
  • Page 43 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-111 4. Installing rails for Drive Box (NBX) The rail install procedure is different depending on the hole shape (square or circular hole) on the rack. Check the holes on the rack before the installation work.
  • Page 44 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-112 (2) Bring down two Clips on the front and rear edge of the rail. (3) Fit Positioning Pins of the rail (four pins in total on the front and back edge) into holes on the right side of the rack at the position where you want to install the Drive Box.
  • Page 45 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-113 (5) Tighten the screw (SBB-RAIL) and the loop cable tie on the rear edge of the rail to fix the rail to the rack. The fixing position is the fourth hole from the bottom of the unit boundary line.
  • Page 46 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-120 5. Installing rails for HSNBX Table 3-5 shows components for the Rail (RRHSN) for HSNBX. Table 3-5 Components for Rail (RRHSN/RRHSNE) (Per Unit) Item No. Parts name Parts No.
  • Page 47 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-130 NOTE : • There are the rail (R) and the rail (L). Check that with the marking on the rail. • These rails extend or shorten back and forth •...
  • Page 48 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)03-01-140 Figure 3-16 Installing Rails for HSNBX (with Stopper) Rack frame (rear side) Unit boundary Rail (R) Unit boundary Clip Unit boundary Unit boundary Clip Rack frame Binding screw (M5 × 10)
  • Page 49: Unpacking Storage Systems

    Hitachi Proprietary DKC910I Rev.3 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)04-01-10 4. Unpacking Storage Systems • The unpacking should be done by two or more workers to prevent turning over of the Storage System or being caught under the Storage System.
  • Page 50 Hitachi Proprietary DKC910I Rev.3 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)04-01-11 2. Labeling DKC910I-CBXA/CBX (1) Attach the nameplates and label, showing corresponding locations to top side and rear side of the CBX. Table 4-1 Nameplate and Label List (CBXA/CBX) Item No.
  • Page 51 Front Rear *1: When DKC-F910I-CTL is not installed in DKC910I-CBX, use the nameplate of the item No. 4. When DKC-F910I-CTL is installed in DKC910I-CBX, use the nameplate of the item No. 6. (2) Attach the nameplates and label, showing corresponding locations to top side and rear side of the HSNBX.
  • Page 52 Hitachi Proprietary DKC910I Rev.3 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)04-01-12A Figure 4-3 Attachment of Nameplates and Label HSNBX NAMEPLATE Hitachi Vantara Rear HSN Box Chassis Primary Controller Chassis MDKC9101-HSNBX DKC9101-CBXA XXXXXXXX 2857688-028 2857688-001 Item No. 3 Item No. 1...
  • Page 53 Hitachi Proprietary DKC910I Rev.3 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)04-01-13 DKC-F910I-CBXB/CBX2 (1) Attach the nameplates and label, showing corresponding locations to top side and rear side of the CBX. Table 4-2 Nameplate and Regulatory label List (CBXB/CBX2) Item No.
  • Page 54 Hitachi Proprietary DKC910I Rev.3 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)04-01-13A Figure 4-4 Attachment of Nameplates and Label CBX (DKC-1) NAMEPLATE Hitachi Vantara Rear Controller Chassis Secondary Controller Chassis MDKC9101-CBX XXXXXX DKC-F910I-CBX2 2857688-027 2857688-053 Item No. 1 Item No. 2...
  • Page 55 Hitachi Proprietary DKC910I Rev.3 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)04-01-14 Figure 4-5 Attachment of Nameplates and Label CBX (DKC-2 or DKC-4) NAMEPLATE Hitachi Vantara Rear Controller Chassis Secondary Controller Chassis MDKC9101-CBX XXXXXX DKC-F910I-CBX2 2857688-027 2857688-053 Item No. 1 Item No. 2...
  • Page 56 Hitachi Proprietary DKC910I Rev.3 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)04-01-14A Figure 4-6 Attachment of Nameplates and Label CBX (DKC-3 or DKC-5) NAMEPLATE Hitachi Vantara Rear Controller Chassis Secondary Controller Chassis MDKC9101-CBX XXXXXX DKC-F910I-CBX2 2857688-027 2857688-053 Item No. 1 Item No. 2...
  • Page 57 Hitachi Proprietary DKC910I Rev.3 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)04-01-15 DKC-F910I-UBX/UBXE (1) Attach the nameplates and label, showing corresponding locations to top side and rear side of the UBX. (2) Attach the nameplates and label to the other UBX in the same manner.
  • Page 58 Hitachi Proprietary DKC910I Rev.3 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)04-01-16 DKC-F910I-SBX (1) Attach the nameplates and label, showing corresponding locations to top side and rear side of the SBX. (2) Attach the nameplates and label to the other SBX in the same manner.
  • Page 59 Hitachi Proprietary DKC910I Rev.3 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)04-01-17 DKC-F910I-FBX (1) Attach the nameplates and label, showing corresponding locations to top side and rear side of the FBX. (2) Attach the nameplates and label to the other FBX in the same manner.
  • Page 60 Hitachi Proprietary DKC910I Rev.3 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)04-01-17A Figure 4-9 Attachment of Nameplates and Label Attachment Locations of Protection sheet Nameplates NAMEPLATE Hitachi Vantara Flash Drive Chassis Flash Drive Chassis(2U) DKC-F9101-FBX XXXXXXXX MNF100R9-BOX 2857688-033 2857688-032 Rear Item No. 1 Item No.
  • Page 61 Hitachi Proprietary DKC910I Rev.3 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)04-01-18 DKC-F910I-NBX (1) Attach the nameplates and label, showing corresponding locations to top side and rear side of the NBX. (2) Attach the nameplates and label to the other NBX in the same manner.
  • Page 62 Hitachi Proprietary DKC910I Rev.3 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)04-01-20 3. Checking the Storage System configuration and supplements (1) Check if the components of the Storage System (their model names, product serial numbers, and quantities) agree with those in the packing list shipped.
  • Page 63: Removing Components

    Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)05-01-10 5. Removing Components 1. Work Procedure before Installing the Rack Mounting When installing the rack by the special lifter, install it in the rack frame with each part installed. (Work “6.
  • Page 64: Removing Drives

    Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)05-01-20 5.1 Removing Drives The drive removal procedure for UBX is different from that for SBX/FBX/NBX. 5.1.1 Removing Drives for UBX 1. Remove the Front Bezel. (See “In Case of SBX/UBX/FBX/NBX” (INST(GE)04-05-20).) 2.
  • Page 65: Removing Drives For Sbx/Fbx/Nbx

    Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)05-01-30 5.1.2 Removing Drives for SBX/FBX/NBX 1. Remove the Front Bezel. (See “In Case of SBX/UBX/FBX/NBX” (INST(GE)04-05-20).) 2. Remove the Drive or a dummy (Drive). Pull the stopper of the handle toward you to have the lock off, tilt the handle toward you, and then remove the Drive by pulling it out taking care not to apply a shock to it.
  • Page 66 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)05-01-40 Figure 5-3 Removing Drive (FBX) SHIELD SPRING Drive Rail Handle Stopper Drive Address label Safekeeping box [INST(IN)05-01-40]...
  • Page 67: Removing Controller Board And The Built-In Parts

    Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)05-02-10 5.2 Removing Controller Board and the Built-in Parts The built-in parts of the Controller Board include a Channel Board and a Disk Board. 5.2.1 Removing Controller Board for DKC and Built-in Parts 1.
  • Page 68 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)05-02-20 2. Remove the Controller Board. Dropping the Controller Board may cause injury. Be aware of the red line marked on the Controller Board top - when sliding the Controller Board out of the array past this mark, keep a firm hold on the Controller Board.
  • Page 69 Hitachi Proprietary DKC910I Rev.0.5 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)05-02-30 3. Remove the Channel Board, HIE, or Disk Board. (1) Loosen two screws (blue) fixing the Board. (2) Hold the screws (blue) and pull out the Channel Board, HIE, or the Disk Board to remove.
  • Page 70: Removing Enc

    Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)05-03-10 5.3 Removing ENC 5.3.1 Removing ENC for SBX/UBX/FBX/NBX NOTICE: • Do not touch the main edge connector of the ENC directly because it is breakable. • Be careful not to hit the connector when placing the ENC temporarily.
  • Page 71 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)05-03-20 Figure 5-8 Removing ENC (FBX) ENC1 ENC2 Lever Latch Lever [INST(IN)05-03-20]...
  • Page 72: Removing Power Supply

    Hitachi Proprietary DKC910I Rev.0.5 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)05-04-10 5.4 Removing Power Supply The shapes and installation methods of the Power Supply differ depending on each type. Do not make a mistake to mount the Power Supply in the specified position.
  • Page 73: Removing Power Supply (Dbps) For Sbx/Ubx/Fbx/Nbx

    Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)05-04-20 5.4.2 Removing Power Supply (DBPS) for SBX/UBX/FBX/NBX 1. Pull the lever open () while pressing the latch on the Power Supply (DBPS) inward with right thumb (). When the lever is completely opened, the Power Supply (DBPS) comes out forward.
  • Page 74: Mounting On A Rack Frame

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)06-01-10 6. Mounting on a Rack Frame 6.1 Mounting Storage System on a Special Lifter • Rack mounting and lifter operation should only be conducted by a person who has been trained and qualified since the Storage System could turn over or a worker could be caught under the Storage System.
  • Page 75 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0 INST(IN)06-01-20 1. Bring the special lifter close to the Storage System to be mounted and apply the stopper to the lifter. NOTE : When putting the Storage System on the special lifter, be sure to remove the Front Bezel beforehand.
  • Page 76: Mounting Storage System On Rack Frame

    Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)06-02-10 6.2 Mounting Storage System on Rack Frame If the Storage System falls when the elevator of the lifter is at a high position, a personal injury will be caused.
  • Page 77 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0 INST(IN)06-02-20 5. After mounting the Storage System on the rack frame, lower the elevating base to the lowermost position by gently opening the up/down valve of the special lifter and take off the stopper of the lifter.
  • Page 78: Fastening Storage System

    INST(IN)07-01-10 7. Fastening Storage System NOTE: If you use rails other than Hitachi Vantara rails, check that screws securing the rails, and the like, are not protruded from the rack surface on which to install the Controller Chassis and that the rack surface is flat (see “Notes for Installing Controller Chassis”...
  • Page 79 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)07-01-20 2. Fixing Controller Chassis (1) When installing DKC, fix each of the right and left places on the front side of DKC with four bind screws. (2) For the rail type without a stopper, go to Step 3 to install the stoppers.
  • Page 80 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)07-01-30 3. Installing Stoppers Table 7-2 Stopper (for DKC) Components (Per One Unit) Item No. Parts name Parts No. Quantity Comment Stopper (R) 3293036-2 Stopper (for DKC) Stopper (L) 3293036-1...
  • Page 81 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)07-01-40 (3) Fix the stopper (L) with the two binding screws while pressing it downward. (4) Fix the stopper (R) with the two binding screws while pressing it downward. Figure 7-4 Fixing Stoppers (for Rail Type without a Stopper)
  • Page 82: Fixing Drive Box (Sbx/Ubx/Nbx)

    Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)07-02-10 7.2 Fixing Drive Box SBX/UBX/NBX The components for fixing the Drive Box are included in the Front Bezel. Check the table of the components list. Table 7-3 Front Bezel Components List (Per Unit) Item No.
  • Page 83 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)07-02-20 1. Fixing the front side of the Drive Box NOTE : Use parts of the rail for the fixing screw and other products. (Refer to Table 3-2.) (1) Install the Drive Box on the front side of the Rack frame.
  • Page 84 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)07-02-21 (3) Install the Drive Box with the bracket. (4) Fasten the Drive Box to the rack frame with the M5 × 10 binding screws temporarily (two places each at right and left).
  • Page 85 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)07-02-30 2. Attachment and removal of a side bezel (1) Attaching the side bezel When attaching the side bezel, perform the attaching in the following procedure. (a) Attach the side bezel in the procedure  and  to cover the left side of the front side of the Drive Box with the side bezel (L) from the top.
  • Page 86: Fixing Drive Box (Fbx)

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.3 INST(IN)07-03-10 7.3 Fixing Drive Box (FBX) Fix the Drive Box with the parts included in the Front Bezel. Table 7-4 Components of Front Bezel Item No. Parts name Parts No.
  • Page 87 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0.1 INST(IN)07-03-20 2. Attach the plate to the left side of the front of the Drive Box. Figure 7-10 Attachment of Plate Drive Box Plate Front view Plate 3. Attach the side cover to the left side of the front of the Drive Box.
  • Page 88: Fixing Hsnbx

    Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)07-04-10 7.4 Fixing HSNBX Table 7-5 Front Bezel Components List (Per One Unit) Item No. Parts name Parts No. Quantity Comment Front Bezel 5560931-A Front Bezel Binding Screw (M5 × 10)
  • Page 89 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)07-04-20 3. Installing Stoppers Table 7-6 Stopper (for HSNBX) Components List (Per One Unit) Item No. Parts name Parts No. Quantity Comment Stopper (R) 3293037-2 Stopper (For HSNBX) Stopper (L)
  • Page 90 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)07-04-30 (4) Fix the stopper (L) with the two binding screws while pressing it downward. (5) Fix the stopper (R) with the two binding screws while pressing it downward. Figure 7-16 Fixing Stoppers...
  • Page 91: Installing Components

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0 INST(IN)08-01-10 8. Installing Components When the components are not installed, install them. When installed, this work is not necessary. Go to the next step. When installing the parts, hold it in the way that fingertips of the hand putting the wrist strap on touches the metallic portion of the side.
  • Page 92: Installing Drive

    Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)08-01-20 8.1 Installing Drive The drive installation procedure for UBX is different from that for SBX/FBX/NBX. 8.1.1 Installing Drive for UBX 1. Pull the parts out of the Drives safekeeping of component.
  • Page 93 Hitachi Proprietary DKC910I Rev.7 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)08-01-30 Figure 8-2 Drive Mounting Location (UBX) HDD zzz-08 HDD zzz-09 HDD zzz-10 HDD zzz-11 DKU-xy(n) DB-zzz HDD zzz-04 HDD zzz-05 HDD zzz-06 HDD zzz-07 (A label is attached.) HDD zzz-00...
  • Page 94: Installing Drive For Sbx/Fbx/Nbx

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1.1 INST(IN)08-01-40 8.1.2 Installing Drive for SBX/FBX/NBX 1. Pull the parts out of the Drives safekeeping of component. Be sure to install the removed Drive to the original position. 2. Insert the Drive into the position (address) where it was by holding it with the handle.
  • Page 95 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1.1 INST(IN)08-01-41 Figure 8-4 Drive Mounting Location (SBX) DKU-xy(n) (A label is attached.) 9 10 11 9 10 11 Printed slot number DB-zzz DB-(zzz+1) Figure 8-5 Drive Mounting Location (NBX) DKU-xy(n) (A label is attached.)
  • Page 96 Hitachi Proprietary DKC910I Rev.7 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)08-01-42 NOTE: Turn on the LOCATE LED by using Maintenance Utility during maintenance work. If you cannot turn on the LOCATE LED, check the number (*2) shown on the label attached to the lower left part of the front side of SBX/NBX so that you do not confuse the maintenance target.
  • Page 97 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1.1 INST(IN)08-01-50 Figure 8-6 Installing the Drive/Dummy (Drive) (FBX) The procedure for installing a Drive Drive Rail SHIELD SPRING Hook Drive Handle Stopper Address label The procedure for installing a dummy (Drive)
  • Page 98 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.7 INST(IN)08-01-60 Figure 8-7 Drive Mounting Location (FBX) Printed slot number DKU-xy(n) HDD (zzz+1)-03 HDD (zzz+1)-04 HDD (zzz+1)-05 DB-(zzz+1) HDD (zzz+1)-00 HDD (zzz+1)-01 HDD (zzz+1)-02 (A label is attached.) HDD zzz-03...
  • Page 99: Installing Controller Board And The Built-In Parts For Dkc

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0 INST(IN)08-02-10 8.2 Installing Controller Board and the Built-in Parts for DKC 1. Install the Controller Board. Dropping the Controller Board may cause injury. Be aware of the red line marked on the Controller Board top - when sliding the Controller Board out of the array past this mark, keep a firm hold on the Controller Board.
  • Page 100 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)08-02-20 Figure 8-8 Installing the Controller Board (DKC) Screws (blue) Lever Controller Board Lever Screws (blue) NOTE: The above illustrations are for VSP 5500 and VSP 5500H. For VSP 5100 and VSP 5100H, only CTL01 and CTL12 are installed.
  • Page 101 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0 INST(IN)08-02-30 (5) Install four BKMFs in the Controller Board. (a) Keep the lever of BKMF pulled down toward you. (b) Insert the BKMF up to the front of the shield finger.
  • Page 102 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0.5 INST(IN)08-02-40 2. If you install a Channel Board, HIE, or Disk Board, install here. (1) Insert the FC/iSCSI Channel Board, HIE, or Disk Board. (2) Push the Channel Board, HIE, or Disk Board in all the way.
  • Page 103: Installing Enc

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)08-03-10 8.3 Installing ENC 8.3.1 Installing ENC for SBX/UBX/FBX/NBX NOTICE: • Do not touch the ENC connector directly because it is breakable. • Be careful not to hit the connector when inserting the ENC.
  • Page 104 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0.1 INST(IN)08-03-20 Figure 8-12 Installing ENC (FBX) ENC1 Lever ENC2 Lever [INST(IN)08-03-20]...
  • Page 105: Installing Power Supply (Dkcps)

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0.5 INST(IN)08-04-10 8.4 Installing Power Supply (DKCPS) The shapes and installation methods of the Power Supply differ depending on each type. Do not make a mistake to mount the power supply in the specified position.
  • Page 106: Installing Power Supply (Dbps) For Sbx/Ubx/Fbx/Nbx

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)08-04-20 8.4.2 Installing Power Supply (DBPS) for SBX/UBX/FBX/NBX 1. With the lever completely opened, insert the Power Supply (DBPS) into the slot. If you cannot insert the Power Supply (DBPS) into the slot easily, insert it after adjusting the position by slightly returning the lever.
  • Page 107: Attach The Chb Port Number Labels

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)08-05-10 8.5 Attach the CHB port number labels CHB port number labels will be attached to the backside of a DKC for evry DKC number and CTL number according to CBX-pair configuration.
  • Page 108 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)08-05-20 1. Remove the appropriate one from the sheet. 2. Attach the CHB port number label to the location for every CTL of DKC (See Figure 8-16 Figure 8-19). 3. Check whether the arrow of the label points to the channel board side after attaching the label.
  • Page 109 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)08-05-30 Figure 8-18 Label attachment (2/3) 1K 3K 5K 7K 1M 3M 5M 7M 1K/3K/5K/7K 1M/3M/5M/7M 1P 3P 5P 7P 1R 3R 5R 7R 1P/3P/5P/7P 1R/3R/5R/7R DKC - 2 CTL22...
  • Page 110 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)08-05-40 Figure 8-19 Label attachment (3/3) 9B BB DB FB 9D BD DDFD 9B/BB/DB/FB 9D/BD/DD/FD 9F BF DF FF 9H BH DHFH 9F/BF/DF/FF 9H/BH/DH/FH DKC - 4 CTL42 CHB Po r t Numb e r...
  • Page 111: Connecting Cables

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)09-01-10 9. Connecting Cables NOTICE: Take full care to connect cables correctly. Route the cables not to affect the maintenance part replacement. Because operation of the Storage System is affected by the cable routing, follow the “Note at the Time of Cable Routing”...
  • Page 112 Hitachi Proprietary DKC910I Rev.0.5 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-01-20 Figure 9-1 Cable Connection (CHB:Fibre Channel) (DKC × 2 + HSNBX × 2 + SBX/FBX) :Power cables :Fibre Channel cables :SAS cables *1: This is a connection example when connecting a power cable to PDU6 (breaker rating: 10 A).
  • Page 113 Hitachi Proprietary DKC910I Rev.0.5 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-01-30 Figure 9-2 Cable Connection (CHB:Fibre Channel) (DKC × 2 + HSNBX × 2 + SBX/FBX) :Power cables :iSCSI cables :SAS cables *1: This is a connection example when connecting a power cable to PDU6 (breaker rating: 10 A).
  • Page 114 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0.5 INST(IN)09-01-40 Figure 9-3 Cable Connection (CHB:Fibre Channel) (DKC × 2 + HSNBX × 2) :X path cables [INST(IN)09-01-40]...
  • Page 115: Connecting Interface Cables

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0 INST(IN)09-01-50 9.1 Connecting Interface Cables Table 9-2 show correspondences between the connector shapes and cable types. Choose the applicable cables from the table correctly. Table 9-2 Connecting Interface Cables Host computer side...
  • Page 116: Connecting Fibre Channel Cables

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0.5 INST(IN)09-01-60 9.1.1 Connecting Fibre Channel Cables 1. Connect the Fibre Channel cables after making sure of the ports to be connected on the rear face of the Storage System. NOTE : When bending the Fibre Channel cable to connect it, give it a bend with a long radius (not less than 40 mm) so as not to apply the cable and the connector excessive stresses.
  • Page 117 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0.5 INST(IN)09-01-70 Figure 9-5 Connection Port for Fibre Channel Cables (16 Gbps (4 Port) FICON/16, 32 Gbps (4 Port) FC) (2/2) CHB Port Number 2K/4K/6K/8K 2M/4M/6M/8M 2P/4P/6P/8P 2R/4R/6R/8R 2J/4J/6J/8J 2L/4L/6L/8L 2N/4N/6N/8N...
  • Page 118 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0.5 INST(IN)09-01-80 2. Pull all the Fibre Channel cables into the rack frame passing them through an opening for cables on the bottom plate of the rack frame. 3. Connect the Fibre Channel cable to the connector of the each port.
  • Page 119: Connecting Iscsi Cables

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0.5 INST(IN)09-01-90 9.1.2 Connecting iSCSI Cables 1. Connect the iSCSI cables after making sure of the ports to be connected on the rear face of the Storage System. NOTE : When bending the iSCSI cable to connect it, give it a bend with a long radius (not less than 40 mm) so as not to apply the cable and the connector excessive stresses.
  • Page 120 Hitachi Proprietary DKC910I Rev.0.5 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-01-100 Figure 9-8 Connection Port for iSCSI Cables (2/2) CHB Port Number 2K/4K 2M/4M 2P/4P 2R/4R 2J/4J 2L/4L 2N/4N 2Q/4Q Rear view of DKC-3 9B/BB 9D/BD 9F/BF 9H/BH 9A/BA 9C/BC...
  • Page 121 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0.5 INST(IN)09-01-110 2. Pull all the iSCSI cables into the rack frame passing them through an opening for cables on the bottom plate of the rack frame. 3. Connect the iSCSI cable to the connector of the each port.
  • Page 122: Connecting X-Path Cables

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0.5 INST(IN)09-02-10 9.2 Connecting X-Path Cables 9.2.1 Precautions when Connecting X-Path Cables NOTE: • The rubber cap is attached to the X-path cable connector. Remove the rubber cap before connecting the X-path cable.
  • Page 123 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-02-20 1. Cable types and selection criteria (1) There are two types of X-path cables: copper and optical cables. The following table lists the cable models. Table 9-3 List of X-Path Cables...
  • Page 124 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-02-21 (c) The rack depth (between the rack front mount angle and rack rear surface) is 960 mm or more. For the rack with a depth less than 960 mm, use the optical cables because the copper cables touch the rack rear surface.
  • Page 125 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0 INST(IN)09-02-30 2. Attachment of cable color codes (1) Check the locations of the DKCs to which the X-path cables are connected (see “Storage System Cable Diagram” (LOC05-10)). (2) Choose a corresponding cable color code among the labels that come with a DKC.
  • Page 126 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-02-40 Table 9-4 Color List of Cable Color Codes Content Location Label Color Color Name Remarks DKC No. DKC-0 (Node0) DKC-1 (Node1) Orange DKC-2 (Node2) Yellow DKC-3 (Node3) Green DKC-4 (Node4)
  • Page 127: Connection Of X-Path Cables

    Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-02-50 9.2.2 Connection of X-Path Cables NOTE: • When bending the X-path cable to connect it, give it a bend with a long radius (not less than 40 mm) so as not to apply the cable and the connector excessive stresses.
  • Page 128 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-02-60 (1) Connect the X-path cables to each HIE according to Figure 5-9 (LOC05-70) through Figure 5-12 (LOC05-90). Eight cables need to be connected for VSP 5100 and 5100H, while 16 cables need to be connected for VSP 5500 and 5500H.
  • Page 129 Hitachi Proprietary DKC910I Rev.0.5 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-02-70 2. X-path cable routing (1) Copper X-path cable routing A routing example of the copper X-path cables is shown in the figure below. Figure 9-14 X-Path Cable Routing Example...
  • Page 130 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-02-80 (2) Optical X-path cable routing A routing example of the optical X-path cables is shown in the figure below. Figure 9-15 X-Path Cable Routing Example (1/2) Clamp Tape HSNBX-1...
  • Page 131 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-02-90 Figure 9-17 X-Path Cable Routing Example (1/2) Figure 9-18 ① X-path Cable (Optical) X-path Cable (Optical) HSNBX-1 Clamp Tape HSNBX-0 DKC-1 DKC-0 Rear view of rack [INST(IN)09-02-90]...
  • Page 132 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-02-91 Figure 9-18 X-Path Cable Routing Example (2/2) Figure 9-18 ① X-path Cable (Optical) Clamp Tape DKC-3 DKC-2 DKC-4 DKC-5 X-path Cable (Optical) [INST(IN)09-02-91]...
  • Page 133: Connecting Lan Cables

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.2 INST(IN)09-03-10 9.3 Connecting LAN Cables 9.3.1 Internal LAN Cable Connect the LAN cables between HSNBX and DKC, between DKCs, or between HSNBXs. 1. The LAN cable kit (DKC-F910I-LC/LCP) for relay connection and the LAN cables (DKC-F910I- LC06/LC5/LC5P/LC10/LC10P/LC20/LC20P/LC30/LC30P/LC1J/LC1JP) are required for LAN cable connection to the LAN ports (U0-U3, L0-L3) on SSVP.
  • Page 134 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-03-20 2. Install the LAN cable kits. Insert the LAN cable kit for relay connection into the cable duct on the rear left side of HSNBX, and then pull out the kit to the front side.
  • Page 135 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-03-21 VSP5100 and 5100H SSVP1 in which SSVP1 is not installed Cable duct HSNBX-1 HSNBX-0 To ports U0-U3 Rear view LAN cable kit VSP5100 and 5100H in which SSVP1 is installed...
  • Page 136 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.2 INST(IN)09-03-30 (1) Remove the protection bag from the LAN cable kit. (2) Attach the four labels to per LAN cable kit. (3) Connect the LAN cable kit to the LAN ports on SSVP.
  • Page 137 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-03-40 (5) Attach the four labels to the connectors for the rear connection per LAN cable kit. Figure 9-22 Attaching Labels LAN Cable Kit Connected to Upper Four Ports LAN cable kit...
  • Page 138 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-03-50 3. Install the LAN cables. • For VSP 5500 and VSP 5500H in which SSVP1 is not installed (1) Connecting the LAN cables to the upper LAN ports on SSVP0 via the LAN cable kit.
  • Page 139 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-03-51 (2) Connecting the LAN cables to the lower LAN ports on SSVP0 via the LAN cable kit. (a) Connect the LAN cables between the LAN port (L0) on SSVP0 and the LAN board 1 (Management LAN port) on DKC-2.
  • Page 140 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-03-52 Figure 9-24 Connecting LAN Cables Front view of HSNBX-0 HSNBX-0 前面 HSNBX-1 (SSVP 0) (SSVP0) HSNBX-0 LAN cable kit (SSVP0, L0-L3) LAN cable Rear view L0-DKC2 L1-DKC3 L2-DKC4 L3-DKC5...
  • Page 141 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-03-53 • For VSP 5500 and VSP 5500H in which SSVP1 is installed (1) Connect the LAN cables to the upper LAN ports on SSVP0 via the LAN cable kit.
  • Page 142 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-03-54 Figure 9-25 Connecting LAN Cables HSNBX-1 前面 Front view of HSNBX-1 (SSVP 1) (SSVP1) HSNBX-1 HSNBX-0 HSNBX-0 前面 Front view of HSNBX-0 (SSVP 0) (SSVP0) LAN cable kit (SSVP1, U0-U3)
  • Page 143 Hitachi Proprietary DKC910I Rev.1.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-03-60 (3) Connect the LAN cables to the lower LAN ports on SSVP0 via the LAN cable kit. (a) Connect the LAN cables between the LAN port (L0) on SSVP0 and the LAN board 1 (Management LAN port) on DKC-2.
  • Page 144 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-03-61 Figure 9-26 Connecting LAN Cables HSNBX-1 前面 Front view of HSNBX-1 (SSVP 1) (SSVP1) HSNBX-1 HSNBX-0 HSNBX-0 前面 Front view of HSNBX-0 (SSVP 0) (SSVP0) LAN cable kit (SSVP1, L0-L3)
  • Page 145 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)09-03-70 • For VSP 5100 and VSP 5100H in which SSVP 1 is not installed (1) Connecting the LAN cables to the upper LAN ports on SSVP0 (a) Connect the LAN cable between the LAN port (U1) on SSVP0 and the Management LAN port on the LAN board 1 in DKC-0.
  • Page 146 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)09-03-80 • For VSP 5100 and VSP 5100H in which SSVP 1 is installed (1) Connecting the LAN cables to the upper LAN ports on SSVP0 (a) Connect the LAN cable between the LAN port (U1) on SSVP0 and the Management LAN port on the LAN board 1 in DKC-0.
  • Page 147 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.2 INST(IN)09-03-90 4. LAN cable routing Routing examples of the LAN cable are shown in Figure 9-29 Figure 9-30. Figure 9-29 When Routing LAN Cables under the Racks HSNBX-1 HSNBX-0 DKC-1...
  • Page 148: External Lan Cable

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)09-03-100 9.3.2 External LAN Cable 1. Use purpose of external LAN cable The external LAN cables connected to the LAN ports on SVP and SSVP in HSNBX are used for three purposes shown in the table below.
  • Page 149 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)09-03-110 2. LAN cable routing procedure • When connecting the LAN cable to SVP-BASIC or SSVP0 (1) Remove the Front Bezel from HSNBX-0 (see “How to Attach/Remove the Front Bezel”...
  • Page 150: Connecting Sas Cables/Nvme Cables

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)09-04-10 9.4 Connecting SAS Cables/NVMe Cables Connect a Controller Chassis and a Drive Box or a Drive Box and another Drive Box with the SAS cable or the NVMe cable.
  • Page 151 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)09-04-11 NOTE: The NVMe cable consists of two cables attached to connectors. Be careful not to pass another cable between the two cables. Figure 9-34 Note on the NVMe Cable...
  • Page 152: Connecting Sas Cables/Nvme Cables

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)09-04-20 9.4.2 Connecting SAS Cables/NVMe Cables NOTE : • The length of the SAS cable/NVMe cable that can be connected to a Controller Board (1PATH) is limited to: ‒ VSP 5100, 5500, 5100H, 5500H : 135 m or less •...
  • Page 153 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.1 INST(IN)09-04-30 (2) The copper cables can be used in one rack only when the following conditions are met. For the other cases, use the optical cables. • SBX/FBX/NBX is installed adjacent to the basic 10U space.
  • Page 154 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-04-40 • The additional DKC (CBX Pair 1: DKC-2/DKC-3, CBX Pair 2: DKC-4/DKC-5) and SBX/FBX/ NBX are installed with a gap of 2U or less. Table 9-10 SAS Cable/NVMe Cable Connection and Copper Cable Length (CBX Pair 1)
  • Page 155 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-04-50 • SBX/FBX and SBX/FBX are adjacently installed. [Cable length: 1 m] • SBX/FBX and UBX are adjacently installed. [Cable length: 1.5 m] (Both the connection from SBX/FBX to UBX and the connection from UBX to SBX/FBX are allowed.)
  • Page 156 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-04-60 2. Attachment of cable color codes (1) Check the locations of the DKCs to which the SAS cables/NVMe cables are connected (see “SAS Cable/NVMe Cable Diagram” (LOC05-10)). (2) Choose a corresponding cable color code among the color codes that come with a DKC.
  • Page 157 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-04-61 Figure 9-36 Attachment of Cable Color Codes (NVMe) Copper Cable Cable color code PATH No. Copper cable Cable color code PATH No. [INST(IN)09-04-61]...
  • Page 158 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-04-70 Table 9-12 Color List of Cable Color Codes Content Location Label Color Color Name Remarks PATH No. PATH#1 (DKC-0/2/4) PATH#2 Orange PATH#3 Yellow PATH#4 Green PATH#5 Light blue PATH#6...
  • Page 159 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-04-80 3. Connection of SAS Cables/NVMe Cables Connect the SAS cables/NVMe cables by following the procedure below according. Check the connection locations of the connectors referring to “Storage System Cable Diagram”...
  • Page 160 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-04-90 (1) Connect the cables to the OUT ports according to Figure 5-1 (LOC05-10) or Figure 5-2 (LOC05-11). Eight cables need to be connected for VSP 5100 and 5100H, while 16 cables need to be connected for VSP 5500 and 5500H.
  • Page 161 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-04-100 (3) Connect the 16 cables to the OUT ports on DBs according to Figure 5-4 (LOC05-30) or Figure 5-6 (LOC05-50) for UBX. Example of the cable  : Connect the cable to which the red label is attached to the ENCxxx-1 OUT0...
  • Page 162 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-04-110 4. Routing of SAS cables/NVMe cables. For the extra length of the connected SAS cable/NVMe cables, keep a length (approx. 350 mm to 400 mm) to insert/pull out the cables and fix it by omega clips.
  • Page 163 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-04-111 Figure 9-40 SAS Cable Routing Example (1/2) SAS Cable Clamp Tape DKC-1 DKC-0 Clamp Tape SAS Cable [INST(IN)09-04-111]...
  • Page 164 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-04-112 Figure 9-41 SAS Cable Routing Example (2/2) SAS Cable Clamp Tape DKC-1 DKC-0 Clamp Tape SAS Cable [INST(IN)09-04-112]...
  • Page 165: Connecting Power Cables

    Hitachi Proprietary DKC910I Rev.4 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-05-10 9.5 Connecting Power Cables 9.5.1 Connecting AC Power Cable • Make sure that there is no scratch or flaw on a power cable. It can cause an electric shock or even a fire.
  • Page 166 Hitachi Proprietary DKC910I Rev.4 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-05-20 7. Route the power cables. 8. Push in the plug of the power cable which has been inserted into the PDU again. It may be loosened owing to a routing.
  • Page 167 Hitachi Proprietary DKC910I Rev.4 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-05-21 Figure 9-42 Connecting Power Cables to the RKU Rack Frame Cable clamp Power cable Power cable Repeat binder [INST(IN)09-05-21]...
  • Page 168 Hitachi Proprietary DKC910I Rev.2 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-05-30 Figure 9-43 Power Cable Routing (Example: DKCx2+HSNBXx2+UBXx4) Power cable Power cable Repeat binder Repeat binder [INST(IN)09-05-30]...
  • Page 169: Connecting Power Cables (Rack Frame Pdu)

    Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)09-06-10 9.6 Connecting Power Cables (Rack Frame PDU) • Make sure that there is no scratch or flaw on a power cable. It can cause an electric shock or even a fire.
  • Page 170: Attaching Decoration Panels

    Hitachi Proprietary DKC910I Rev.3 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)10-01-10 10. Attaching Decoration Panels When a free space is left on the front side of the rack frame, install the decoration panels there. 1. Fit the decoration panels to the front side of the rack frame one by one starting from the top.
  • Page 171: Setting External Covers

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0 INST(IN)11-01-10 11. Setting External Covers 1. Close the rear door of the rack frame. (Refer to “How to Open/Close the Door of the RKU Rack Frame” (INST(GE)04-06-10).) 2. Attach the Front Bezel. (Refer to “How to Attach/Remove the Front Bezel” (INST(GE)04-05-10).)
  • Page 172: Attaching Logo

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.2 INST(IN)12-01-10 12. Attaching Logo NOTE: This procedure should be applied at the time of shipment in the factory. 1. Attach the logo to the Front bezel of the DKC-1. 2. After attaching the logo, peel off the clear protection film of the logo.
  • Page 173: Connecting The Maintenance Pc To Svp With Lan Cables

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0.1 INST(IN)13-01-10 13. Connecting the Maintenance PC to SVP with LAN Cables 13.1 Specifications for the Maintenance PC A laptop PC that can be used as the Maintenance PC must meet specifications shown in Table 13-1.
  • Page 174: Attachment/Removal Procedure Of Maintenance Pc

    Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0 INST(IN)13-02-10 13.2 Attachment/Removal Procedure of Maintenance PC 1. Attachment Procedure of Maintenance PC (1) Remove the Front Bezel from HSNBX-0 or HSNBX-1. (Refer to (INST(GE)04-05-60) (2) Connect the power cable and LAN cable to the Maintenance PC.
  • Page 175 Hitachi Proprietary DKC910I Copyright © 2019, 2021, Hitachi, Ltd. Rev.0 INST(IN)13-02-20 Figure 13-1 Connection of Cables HSNBX-1 SVP-OPTION (*1) SSVP1 (*1) SVP-BASIC SSVP0 HSNBX-0 CONSOLE SSVP *1: Only when the SVP High Reliability Kit is installed, SSVP is installed in SSVP1 and SVP is installed in SVP-OPTION.
  • Page 176: New Installation Svp Procedure

    Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-01-10 14. New Installation SVP Procedure 14.1 New Installation procedures without the pre-installation at a customer site 14.1.1 Application These procedures are applied to a new installation without the pre-installation at a customer site or the pre- installation at the warehouse as shown below.
  • Page 177: Conditions To Use These Procedures

    Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-01-20 14.1.2 Conditions to use these procedures These procedures can be used in the following conditions: 1. The installation of the Hardware parts (for example, the connections of cables, power supplies and so on) have been finished.
  • Page 178: Procedures

    Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-01-30 14.1.3 Procedures 1. Summary The procedures are divided roughly into 3 processes. (1) Pre-processing (the installation of the micro-programs into the SVP HD : (1)-(8) in the following flow) (2) Execution of “New Installation”...
  • Page 179 Connect to the SVP display from the Maintenance PC by the remote desktop. step2: Prepare the media. step3: Uninstall any additional software installed on the SVP such as Hitachi Remote Ops/C-Track and Anti-Virus client. step4: Insert the media disk into the Maintenance PCʼs drive.
  • Page 180 Hitachi Proprietary DKC910I Rev.1.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-01-50 step5: Enter the following command: \\tsclient\E\xxxxx.exe (*10) (enter). * In the case Maintenance PCʼs media drive is “E:”. Message is displayed: “(SUP4186W) Initializing the SVP that is currently operating. Do you want to continue?”...
  • Page 181 Hitachi Proprietary DKC910I Rev.1.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-01-60 (10) Before starting the following procedure, you need to enable the CE mode. For the procedure for enabling the CE mode, see “Setting the jumper used for initial installation (CEMD)”.
  • Page 182 Hitachi Proprietary DKC910I Rev.1.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-01-70 (SVP procedure) (19) Check storage system status and micro-versions of each MP. <Micro-versions: (SVP03-05-10), Storage system status: (MU02-10)> (20)-1 Execute the “On-line Micro-program Exchange” for the GUM. (MICRO03-10) (20)-2 Execute the “On-line Micro-program Exchange” for the SSVP, Expander, CFM and so on.
  • Page 183 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-01-80 *1 : Even if the “IP Address” is “126.255.254.15” and the “Subnet Mask” is “255.0.0.0” on the screen of “Set IP Address”, be sure to select “OK” and reply “OK” to the message “This will reboot SVP.”.
  • Page 184 Hitachi Proprietary DKC910I Rev.1.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-01-90 *8: The Following tables show all the configuration key codes. Type Configuration key code VSP5 *9: Please contact the Technical Support Division to request the password. *10: The executable file name varies depending on the micro-program version.
  • Page 185: Procedure Of New Installation Of The Micro-Program

    Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-10 14.2 Procedure of New Installation of the Micro-program 14.2.1 TOD Setting and Set IP Address [1] TOD Setting (Turn on storage system power before TOD Setting) 1. <Open the Control Panel window>...
  • Page 186 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-20 2. <Open [Date and Time]> Click [Date and Time] in the Control Panel window. 3. <Selecting [Change time zone]> Click [Change time zone...]. [INST(IN)14-02-20]...
  • Page 187 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-21 4. <Check the setting of [Time zone]> Check that the “Time Zone” is set as follows regardless of where the storage system is placed: (UTC) Coordinated Universal Time 5. <Set [Date and Time Settings]>...
  • Page 188 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-30 10. Click [Set Subsystem Time] in the Install window. 11. Select [TOD Change] in the Set Subsystem Time window, and then click [OK]. 12. Specify the date (year, month and day) and time (hour, minute and second) and click [OK].
  • Page 189 Hitachi Proprietary DKC910I Rev.6 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-40 [2] Set IP Address NOTICE: • When the SVP High Reliability Kit is installed, setting of the IP addresses for both Master SVP and Standby SVP is required. Firstly set IP Address of Standby SVP.
  • Page 190 Hitachi Proprietary DKC910I Rev.6 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-50 4. <Change the IP Address> (1) Select [SVP] and setting IP Address and Subnet Mask of an Internal IP Address. The case when SVP High Reliability kit is installed. Check [Use Duplex SVP], and check in the SVP Kind.
  • Page 191 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-60 The SVP High Reliability kit un-setting up The SVP High Reliability kit setting up (Master SVP) The SVP High Reliability kit setting up (Standby SVP) (2) Click [OK] in response to the confirmation message [INS3325W].
  • Page 192 Hitachi Proprietary DKC910I Rev.7 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-70 (3) <Backup for configuration information> (a) The message [CNF3686i] is displayed. Select “SSVP”, and then click [OK]. NOTE: When you change the IP address of Standby SVP, backup of the configuration information is unnecessary.
  • Page 193 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-80 (4) In response to the message [INS1105i], click [OK]. Change the IP Address is abnormally terminated if the message “Failed to change the IP address.” is displayed. Identify the error cause according to the procedure shown in “TROUBLE SHOOTING SECTION”...
  • Page 194: Configuration Information Definition

    Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-90 14.2.2 Configuration Information Definition NOTICE: Before starting the following procedure, you need to enable the CE mode. For the procedure for enabling the CE mode, see “Setting the jumper used for initial installation (CEMD)”...
  • Page 195 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-100 (2) Click [Initial Setting]. The Initial Setting window opens. (3) Click [NEW Installation] in the Initial Setting window. [INST(IN)14-02-100]...
  • Page 196 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-110 This is a special (exceptional) operation that can cause a serious failure such as a system down or a data loss if executed in an occasion other than the new storage system installation, and requires an input of a password.
  • Page 197 Hitachi Proprietary DKC910I Rev.1.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-120 (7) Password [3357] window is displayed. Enter the password and click [OK] . For the password, contact the Technical Support Division. (8) In response to the message “Select the number of target DKC for New Installation.”, select the number of DKCs, and then click [OK] .
  • Page 198 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-130 (9) Response to the message “[4279] This operation requires the storage system running in the CE mode. Check status of the storage system. Select [Yes] when the storage system is already running in the CE mode.
  • Page 199 Hitachi Proprietary DKC910I Rev.7 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-140 (11) Select the drive The message [CNF3683i] is displayed. Select the Maintenance PC drive into which the micro-program media is inserted, and then click [OK]. (12) Make a copy of the configuration information.
  • Page 200 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-150 (14) Click [OK] in response to the confirmation message “[2565] Installation data of program product in the Configuration table will be initialized by this operation. After finishing this procedure, please set the program product installation again.”.
  • Page 201 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-160 (17) Click [OK] in response to the message “[3697] A setting of a machine installation date has ended successfully.”. (18) Click [Yes] in response to the confirmation message, “[0462] Are you sure you want to install the defined configuration?”.
  • Page 202 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-170 (20) Click [OK] in response to the confirmation message, “[2585] <Important CAUTION> When you continue this operation, customerʼs DATA is LOST. Are you sure you want to continue this operation?”.
  • Page 203 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-180 (23) Click [OK] in response to the cautionary message, “[2588] <Important CAUTION> You must not RE-BOOT SVP.”. (24) <Compressing of the configuration information> The configuration information is compressed. The dialog of “Config Compressing...” is displayed. After the compressing is completed, go to Step (25).
  • Page 204 Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-190 (26) <Configuration information transfer> The configuration information is forwarded. After the forward is completed, go to Step (27). If you want to confirm the transfer status, click [Detail] . Go to Step (a).
  • Page 205 Hitachi Proprietary DKC910I Rev.5 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-200 (27) Powering off, disabling the CE mode, and then powering on (a) The message [INS4278i] is displayed. Perform the procedures according to the message. At that time, refer “Disabling the jumper used for initial installation (CEMD)”...
  • Page 206: Post Processing

    Hitachi Proprietary DKC910I Rev.0 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-210 14.2.3 Post Processing Check the completion of the storage system setup. 1. Logging in to the Maintenance Utility window Click [Maintenance Utility] in the SVP window. [INST(IN)14-02-210]...
  • Page 207 Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-220 2. Checking status In Maintenance Utility window, confirm the status of the storage system is ”Ready” and SIM is not output. Status Procedure Ready In “SVP”window, check SIM.(*1) There are some failed parts. Check the “MAIN” windows and SIM, then take a Warning necessary action.
  • Page 208: Check Procedure

    Hitachi Proprietary DKC910I Rev.0.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-230 14.2.4 Check Procedure 1. Check System Configuration Check that the system configuration is initialized. 2. Check all MPs micro-program version In the Version window, open the [MP Ver.(Curt./Running)] tab and the [MP Ver.(Curt./FM)] tab to check that the error icon is not displayed.
  • Page 209: Troubleshooting At The Time Of New Installation

    Hitachi Proprietary DKC910I Rev.1.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)14-02-240 14.2.5 Troubleshooting at the Time of New Installation Trouble Recovery action The “Media copy” dialog box displayed The drive specified in the “Select Media dialog” box might be the message “INS3005E”, and the new different from the drive of the media in which the microprogram is...
  • Page 210: Enabling Or Disabling Hsts

    Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)15-01-10 15. Enabling or Disabling HSTS Procedures for enabling and disabling HTTP Strict Transport Security (hereinafter referred to as HSTS) (*1) are as follows: *1: HSTS is a security policy mechanism that allows web servers to declare that web browsers should use HTTPS.
  • Page 211 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)15-01-20 2. Procedure for disabling HSTS (1) Launching the Command Prompt as administrator Select [Start]-[Windows System], right-click the displayed [Command Prompt], and then select [More]-[Run as administrator]. (2) Changing the current directory Run the following command in the Command Prompt.
  • Page 212 Hitachi Proprietary DKC910I Rev.1 Copyright © 2019, 2021, Hitachi, Ltd. INST(IN)15-01-30 3. Confirmation procedure of HSTS setting (1) Launching the Command Prompt as administrator Select [Start]-[Windows System], right-click the displayed [Command Prompt], and then select [More]-[Run as administrator]. (2) Changing the current directory Run the following command in the Command Prompt.

Table of Contents