Hitachi E590 Hardware Reference Manual
Hitachi E590 Hardware Reference Manual

Hitachi E590 Hardware Reference Manual

Virtual storage platform
Hide thumbs Also See for E590:

Advertisement

Hitachi Virtual Storage Platform E590 and
E790
93-04-01
Hardware Reference Guide
This document provides information about the system hardware components and the mechanical and
environmental specifications for the VSP E590 and VSP E790 storage systems.
MK-97HM85050-01
February 2021

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi E590

  • Page 1 Hitachi Virtual Storage Platform E590 and E790 93-04-01 Hardware Reference Guide This document provides information about the system hardware components and the mechanical and environmental specifications for the VSP E590 and VSP E790 storage systems. MK-97HM85050-01 February 2021...
  • Page 2 Hitachi, Ltd., or Hitachi Vantara LLC (collectively “Hitachi”). Licensee may make copies of the Materials provided that any such copy is: (i) created as an essential step in utilization of the Software as licensed and is used in no other manner;...
  • Page 3: Table Of Contents

    Physical specifications..................26 Chapter 4: Turning storage system power on and off......27 Powering on the storage system............... 27 Powering off the storage system................28 Chapter 5: Site preparation..............29 Site preparation checklist...................29 Contents Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 4 Site planning...................... 30 Installation site considerations..............31 Floor cutout and service clearance..............31 Floor load rating....................33 Appendix A: Component list..............34 Component list....................34 Contents Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 5: Preface

    Preface This guide describes the hardware features and specifications of the VSP E590 and VSP E790 storage systems. Intended audience This document is intended for Hitachi Vantara representatives, system administrators, authorized service providers, or customers who configure and operate the VSP E590 and VSP E790 storage systems.
  • Page 6 { a | b } indicates that you must choose either a or b. This document uses the following icons to draw attention to information: Icon Label Description Note Calls attention to important or additional information. Preface Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 7: Accessing Product Documentation

    Getting help Hitachi Vantara Support Website is the destination for technical support of products and solutions sold by Hitachi Vantara. To contact technical support, log on to the Hitachi Vantara Support Website for contact information: https://support.hitachivantara.com/en_us/contact- us.html. Hitachi Vantara Community is a global online community for Hitachi Vantara customers, partners, independent software vendors, employees, and prospects.
  • Page 8: Chapter 1: Introduction

    Chapter 1: Introduction The Hitachi Virtual Storage Platform E590 (VSP E590) and Hitachi Virtual Storage Platform E790 (VSP E790) storage systems are high-performance, large-capacity data storage systems utilizing all-flash NVMe solid-state drives. The storage system consists of a controller chassis and internal components such as fans and PCIe switches.
  • Page 9 Supported channel types Fibre Channel (shortwave, ■ longwave) iSCSI (optical) ■ Data transfer rate Fibre Channel up to 4 GB/s iSCSI (Optical) 10 Gbps Maximum number of front-end modules Chapter 1: Introduction Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 10 Supported channel types Fibre Channel (shortwave, ■ longwave) iSCSI (optical) ■ Data transfer rate Fibre Channel up to 4 GB/s iSCSI (Optical) 10 Gbps Maximum number of front-end modules Chapter 1: Introduction Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 11: Chapter 2: Hardware Overview

    ■ Backup fan module (BKMF) ■ The storage system's CTLs contain the cache memory (CM) and cache flash memory (CFM) for the storage system. The VSP E590 and VSP E790 supports 768 GiB of cache memory. Number Item Description LED (POWER, READY, WARNING,...
  • Page 12 LED might turn off during user maintenance. ALARM LED Off: Normal operation. Red: Processor failure (system might be down). For assistance, contact customer support: https://support.hitachivantara.com/en_us/ contact-us.html. Chapter 2: Hardware overview Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 13 Green: Normal operation. Green Blinking: The drive is being accessed. Drives Disk drives Number Item Description Power supply unit Supplies electric power to the controller components. Chapter 2: Hardware overview Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 14: Controller Board

    Channel board component LAN-RST switch Resets GUM. Use only when instructed by Hitachi Vantara support. LAN port LAN1: Maintenance LAN port (left) LAN2: User LAN port (right) Chapter 2: Hardware overview Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 15: Front-End Modules

    The storage system supports Fibre Channel (FC) and iSCSI front-end modules (FEMs) for attachment to host servers. The front-end module LEDs indicate the operating status of the module. Chapter 2: Hardware overview Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 16: 10-Gbps Iscsi Board Leds And Connectors (Optical)

    1. When 50/125mm laser optimized multi-mode Fibre cable (OM3 or OM4) is used. When using other cable types, contact customer support. 10-Gbps iSCSI board LEDs and connectors (optical) Chapter 2: Hardware overview Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 17: 10-Gbps Iscsi Board Leds And Connectors (Copper)

    Connect to Ethernet cables. Table 3 Port assignments CHB number Port 1 Port 2 CHB-1A CHB-1B CHB-1C CHB-2A CHB-2B CHB-2C 10-Gbps iSCSI board LEDs and connectors (copper) Chapter 2: Hardware overview Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 18 Blinking: Communication is in progress. Off: No link connection or not ready to communicate. Table 4 Port assignments CHB number Port 1 Port 2 CHB-1A CHB-1B CHB-1C CHB-2A CHB-2B Chapter 2: Hardware overview Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 19: 16-Gbps Or 32-Gbps Fibre Channel (4-Port) Board Leds And Connectors

    Blue: Normal link status at 32-Gbps (32-Gbps). Green: Normal link status at 4-Gbps or 8-Gbps (16- Gbps). Green: Normal link status at 8-Gbps or 16-Gbps (32- Gbps). Chapter 2: Hardware overview Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 20: Lan Blade Leds And Connectors

    CHB-1C CHB-2A CHB-2B CHB-2C LAN blade LEDs and connectors Number Item Description LINK LED Green: Link status is normal. ACT LED Orange: Data is being transferred. Chapter 2: Hardware overview Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 21: Rack Support

    (UPS) port Rack support The storage system can be installed in the Hitachi Universal V2B rack as well as non-Hitachi 19-inch racks that meet the storage system's specifications. For details about the Hitachi Universal V2B rack, see the Hitachi Universal V2B Rack Reference Guide.
  • Page 22: Chapter 3: Specifications

    Chapter 3: Specifications The Hitachi Virtual Storage Platform E590 (VSP E590) and Hitachi Virtual Storage Platform E790 (VSP E790) storage systems are designed to operate in a controlled environment such as a data center. The following tables provide the environmental, electrical, and physical requirements and specifications for the VSP E590 and VSP E790.
  • Page 23 Within ANSI/ISA S71.04-2013 G1 classification contaminants levels. Non-operating Keep data center clean by monitoring and controlling gaseous contamination. Table 11 Noise level (recommended) State Specification Operating 90 dB or lower* Chapter 3: Specifications Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 24: Electrical Specifications

    The Hitachi Virtual Storage Platform E590 (VSP E590) and Hitachi Virtual Storage Platform E790 (VSP E790) run on single-phase AC power. The AC power input for the VSP E590 and VSP E790 storage systems have a duplex PDU architecture that enables the equipment installed in the rack to remain powered on if power is removed from one of the two power distribution panels.
  • Page 25 1 phase +10% or -11% 2 wire + ground 50 Hz ±3 Hz 100 V to 120 V 1 phase +10% or -11% 2 wire + ground Chapter 3: Specifications Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 26: Physical Specifications

    Physical specifications The following table provides the physical specifications for the Hitachi Virtual Storage Platform E590 (VSP E590) and Hitachi Virtual Storage Platform E790 (VSP E790) storage systems, including weight, heat output, power consumption, and air flow specifications. Table 14 Weight, heat output, power consumption, and air flow specifications...
  • Page 27: Chapter 4: Turning Storage System Power On And Off

    Use the following procedure to power on the storage system. The main switch on the controller chassis is used to power on the storage system. Chapter 4: Turning storage system power on and off Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 28: Powering Off The Storage System

    To avoid this situation, charge the battery for more than three hours at least once every six months. Chapter 4: Turning storage system power on and off Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 29: Chapter 5: Site Preparation

    Site preparation checklist Verify the availability of each item in the site preparation checklist. The responsibilities for installation planning are shared by the customer and the Hitachi Vantara account team. The required installation planning tasks must be scheduled and completed to ensure successful and efficient installation of the storage system.
  • Page 30: Site Planning

    Review the power and the heating, ventilation, and air-conditioning requirements before ■ ordering any additional support equipment. Make a final layout of the installation and review the layout with the Hitachi Vantara ■ representative. Verify the installation of electrical service wiring at the predetermined location is proper ■...
  • Page 31: Installation Site Considerations

    Provides minimum clearance around the storage system for service access and to verify ■ proper weight distribution on the computer room floor. Includes correctly positioned floor cutouts for the storage system's power and data cables. ■ Chapter 5: Site preparation Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 32 The amount of additional space required depends on your floor load rating. Additional space required to view the storage system LEDs on the front and rear panels. ■ Chapter 5: Site preparation Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 33: Floor Load Rating

    Floor load rating The floor space at the installation site must support the combined weight of all associated component and equipment. The maximum load rating is 709 kg. Chapter 5: Site preparation Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 34: Appendix A: Component List

    DW-F900-CTLMN Controller board DW-F900-CTLMNE Encrypting controller board DW-F900-CM32G Cache memory (32 GB) 2-12 DW-F900-BM70 Cache flash memory non-encrypted (CFM) DW-F900-BM7E Cache flash memory with encryption (CFM) Appendix A: Component list Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 35 DW-F900-4HF32R Front-end module (32/16-Gbps 4port-FC) DKC-F810I-1PS16 SFP for 16 Gbps Shortwave 0-24 DKC-F810I-1PL16 SFP for 16 Gbps Longwave 0-24 DKC-F810I-1PS32 SFP for 32 Gbps Longwave 0-24 Appendix A: Component list Hitachi Virtual Storage Platform E590 and E790 Hardware Reference Guide...
  • Page 36 Hitachi Vantara Corporate Headquarters Contact Information 2535 Augustine Drive USA: 1-800-446-0744 Santa Clara, CA 95054 USA Global: 1-858-547-4526 HitachiVantara.com | community.HitachiVantara.com HitachiVantara.com/contact...

Table of Contents