Quick Connect Fittings (Auxiliary Hydraulic Circuit Only); Quick Connect Removal; Quick Connect Installation - Club Car Carryall 295 Maintenance And Service Manual

Hide thumbs Also See for Carryall 295:
Table of Contents

Advertisement

HYDRAULIC ATTACHMENT SYSTEM

QUICK CONNECT FITTINGS (AUXILIARY HYDRAULIC CIRCUIT ONLY)

2252
Figure 19-36 Quick Connect Fitting Removal

QUICK CONNECT REMOVAL

1.
Relieve pressure in hydraulic system. See Relieving Hydraulic System Pressure on page 19-1.
2.
Set the joystick ON/OFF switch to OFF, remove driver seat and disable vehicle. See Disabling the Vehicle
on page 1-3.
3.
Disconnect battery. See Disconnecting the Battery – Gasoline/Diesel Vehicles, Section 1, Page 1-3.
4.
Thoroughly clean the fittings and the area around them.
5.
Mark hoses to ease reassembly and disconnect hoses from quick connect fittings. See following NOTE. Cover
hoses and fittings to keep out debris.
NOTE: Mark hoses for correct installation if factory markings are not found.
6.
Remove the lock nut securing the quick connect fitting to the bracket (Figure 19-36, Page 19-23).

QUICK CONNECT INSTALLATION

1.
Reverse the removal procedure to install quick connect fittings. Tighten jam nuts to 30 ft-lb (41 N·m).
2.
Match hose to fitting and connect hoses (Figure 19-35, Page 19-22). Tighten fittings to 22 ft-lb (30 N·m).
Quick Connect Fittings (Auxiliary Hydraulic Circuit only)
2013 Carryall 295/XRT 1550 Maintenance and Service Manual
19
Page 19-23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Carryall xrt 1550

Table of Contents