6-5-12. Saves SV Adjustments Data
For explanation of SV0C: SV NV-RAM Save, refer to Section 6-2.
(1) Enter SV0C: SV NV-RAM Save.
(2) Press the Y key to save the adjustment data into NV-
RAM.
(3) When the saving of the data is completed, messages
"Saving NV-RAM....OK" is displayed.
6-5-13. Automatic-Tracking Function Check
Prepares an alignment tape YR5-1. (Check start tape address: IDR: 0 through 72000)
. To move the tape address during check start, use the control software of GY-2120 (after insertion of the
cassette).
For explanation of SV1D: SAT Function Chack, refer to Section 6-2.
(1) Enter SV1D: SAT Function Check
(2) Insert the alignment tape YR5-1.
(3) Press the Y key to initiate the check.
(4) Confirm that the messages "Check Complete" is
displayed.
*
When message "(Tape end detected)" is displayed,
rewind the tape to tape top, then check again.
GY-2120WD/WS
------>SV0C
Servo Adjust [NV-RAM Control]
SV NV-RAM Save
Are you ready (y/n)? Yes
Saving NV-RAM1....OK
Saving NV-RAM2....OK
Data Saved
------>_
------>SV1D
Servo Check
SAT Function Check
Set YR5-1 (Alignment Tape)
Are you ready (y/n/else=Eject)? Yes
Auto Check Start
Check Complete
------>_
6-5. Servo System Alignment
6-199