5-8. Time Code Level Adjustment in Rev Mode
Equipment
. Oscilloscope
. PC (IBM PC/AT compatible machine)
*
For connection of a PC, refer to Section 5-1.
Tools
. Alignment tape YR2-1:
. DTF cassette tape (S cassette)
. Small round type mirror
. Tape guide adjustment driver (MW-261): J-6322-610-A
. GY-2120 control software (remo.exe)
Preparation
1. Turn the Power Off
2. Connect the Oscilloscope
CH-1: TP703/EQ-66 board (LTC ANA signal)
3. Set the Alignment Tape
Set the YR2-1 and put a weight (about 1000 g)
on the cassette so that it does not rise up.
GY-2120WD/WS
8-960-074-11
J-6080-029-A
* Connection of the oscilloscope
CH-1 : TP703/EQ-66 board (LTC ANA signal)
<EQ-66 board, side A>
5-8. Time Code Level Adjustment in Rev Mode
TP703
Preparation
5-31