1-11. GY-2120 SCSI Control Software scsitool.exe
3-4. Process When Error Occurs
Describes the process when errors occur during operations.
3-4-1. When the following contents are output to the log file.
TEST UNIT READY >> ERROR!! <SENSE-KEY [ 2] - ASC [ 4] - ASCQ [ 1]>
Wait until "Loaded" and execute START again.
3-4-2. When the ASPI error occurs
ASPI ERROR!! is output and the process is completed.
This occurs when the "Length" and "Block Size" values for parameter settings are not satisfied.
3-4-3. When the check condition occurs
The code and contents are output and the process is completed.
For details on the codes, refer to the protocol manual.
Example 1:
In this example, "EOM" occurs because the writable area on the tape is limited.
In this case, the process thereafter will be continued as an exceptional case.
WRITE
Example 2:
In this case, the details are output and the process is stopped.
WRITE
1-52
TAPE LOADING
>> ERROR!! <SENSE-KEY [ 0] - ASC [ 0] - ASCQ [ 0]>
EOM bit ON
>> ERROR!! <SENSE-KEY [ 5] - ASC [20] - ASCQ [00]>
INVALID COMMAND