1-13. Download by Special Tool
Check After Downloading
1. Start the terminal software from the PC.
Set the RS-232C port of the PC as follows.
Setting
Setting Value
Serial Port
COM 1 connector at PC side
Baud rate
38400 bps
Parity
None
Flow control
None
Stop Bit Length
1 bit
Data Width Length
8 bits
2. Enter "ROM" from the PC keyboard, and check the version of the downloaded
firmware.
*** ROM VERSION DISPLAY ***
[FW Rev]
XXX. XX
[SCSI]
X. XX
[SYS]
X. XX
[IF]
X. XX
[SV]
X. XX
[EQ]
X. XX
[DR]
X. XX
3. To download a different firmware, execute from step 4 "Downloading Firm-
ware".
4. Turn OFF the power of GY-2120.
5. Disconnect the RS-232C cable of GY-2120.
6. Turn OFF the SET UP switch No. 8 of the GY-2120 rear panel.
7. End