* Causes of problems must be determined before parts are replaced. Therefore use the LOG_Check to aid
the procedure of replacing and checking parts to be replaced.
* The DIAG-Check is intended for checking the main data signal processing systems and control system
circuits by checking general operations of the MEM-83, MA-83, DSP-78, and EQ-66 boards by All
Check.
* Cassette-Man-Eject means to remove the tape from the unit manually with the power OFF, as a "pro-
tection mode" for tape transport system errors in the range of the 2xxx error codes.
For the 1xxx error codes, the cassette can be removed by the emergency eject SW.
* Cleaning means to clean using GW-90CL, as well as cleaning the tape running system using a cleaning
cloth and cleaning liquid during periodic inspections, etc.
* Host-Check indicates checking the operations from the system by analysis of the SCSI bus.
* Other replacement parts list
Error Message
Format?
Memory Check Err
Recover?
Front Panel LED/LCD
LED/LCD does not light up after the power is turned on
Rear Panel LED (TERM POEWER)
LED does not light up even if power is supplied
List of Replacement Parts during Periodic Inspection
Upper drum assembly
Pinch arm assembly
V cleaning roller assembly
Brush SR4 assembly
Filter assembly
Stopper washer
Poly-washer for adjustment (-01)
Poly-washer for adjustment (-11)
GY-2120WD/WS
Processing
Replacement Parts List
Format, ERASE
MEM-83
Recover
Replacement Parts List
DSP-78, SW power supply, fuse, or GY-
2120
Replacement Parts List
IF-682, microfuse, or GY-2120
6-3. Error Processing
6-175