Follow the firmware download instructions in the Oracle ILOM documentation.
You can load any supported system firmware version, including the firmware version
Note -
that was installed prior to replacing the motherboard.
23.
If necessary, reactivate any RAID volumes that existed prior to replacing the
motherboard.
If your server contained RAID volumes prior to replacing the motherboard, see
RAID Volumes" on page 161
24.
Power on the server.
See
"Power On the Server (Oracle ILOM)" on page 180
Power Button)" on page
(Optional) Transfer the serial number and product number to the FRUID of the
25.
new motherboard.
If the replacement motherboard must have the same serial number as the server prior to
servicing, trained service personnel must take this action in a special service mode.
Related Information
Oracle ILOM documentation
"Remove the Motherboard" on page 147
"Reactivate RAID Volumes" on page 161
"Verify the Motherboard" on page 164

Reactivate RAID Volumes

Perform this task only if your server had RAID volumes prior to replacing the motherboard.
1.
Prior to powering on the server, log in to the SP.
Refer to
"Log In to Oracle ILOM" in SPARC T7 Series Servers Administration Guide
instructions.
2.
At the Oracle ILOM prompt, disable auto-boot so that the server will not boot the
OS when the server powers on.
-> set /HOST/bootmode script="setenv auto-boot? false"
3.
Power on the server.
for instructions.
181.
Reactivate RAID Volumes
"Reactivate
or
"Power On the Server (System
Servicing the Motherboard
for
161

Advertisement

Table of Contents
loading