23.
Power on the server.
See
"Power On the Server (Oracle ILOM)" on page 174
Power Button)" on page
24.
(Optional) Transfer the serial number and product number to the FRUID of the
new motherboard.
If the replacement motherboard must have the same serial number as the server prior to
servicing, trained service personnel must take this action in a special service mode.
Related Information
Oracle ILOM documentation
"Remove the Motherboard" on page 147
"Reactivate RAID Volumes" on page 155
"Verify the Motherboard" on page 158

Reactivate RAID Volumes

Perform this task only if your server had RAID volumes prior to replacing the motherboard.
1.
Prior to powering on the server, log in to the SPM.
Refer to Servers Administration for instructions.
2.
At the Oracle ILOM prompt, disable auto-boot so that the server will not boot the
OS when the server powers on.
-> set /HOST/bootmode script="setenv auto-boot? false"
3.
Power on the server.
See
"Power On the Server (Oracle ILOM)" on page 174
Power Button)" on page
4.
At the OpenBoot prompt, list the device paths on the server.
ok show-devs
...
/pci@400/pci@2/pci@0/pci@e/scsi@0
...
You can also use the devalias command to locate device paths specific to your server.
175.
175.
Reactivate RAID Volumes
or
"Power On the Server (System
or
"Power On the Server (System
Servicing the Motherboard
155