Ae Bus Command Status Response (Csr) Codes; Ae Bus Command Set; Table 4-6. Command Status Response (Csr) Codes - Advanced Energy HFV 8000 User Manual

Table of Contents

Advertisement

®
Advanced Energy

AE BUS COMMAND STATUS RESPONSE (CSR) CODES

When the HFV generator receives a command requesting a change in unit operation or
status (command numbers 1 through 127), it responds with a command status
response (CSR) code. The CSR is a single-byte number that indicates whether the unit
accepted or rejected the command and, in the case of rejection, the reason the unit
could not respond to the command. Use

Table 4-6. Command Status Response (CSR) codes

Value
0
The following CSR codes are sent in response to a command that
was not accepted and indicate why the command was not
accepted.
1
2
3
4
5
7
8
9
16
17
19
21
24
28
30
36
99

AE BUS COMMAND SET

The HFV generator AE Bus serial communication interface has two types of
commands:
4-18
Meaning
Command accepted
Control mode is incorrect
Output is on; change not allowed
Output is off; change not allowed
Data is out of range
Invalid parameter
Active fault(s) exist
Ramping is active; change not allowed
Data byte count is incorrect
Target life has been consumed
Output OFF timer active (minimum off time is 50 ms)
Recipe is active; change not allowed
Joule set point has not been reached
Bus fault active (high or low)
Set point exceeds user limit
TCC is active; change not allowed
Data sent is greater than user limit for P, V, or I
Command not accepted (there is no such command)
Communication Interfaces
Table 4-6
to interpret the CSR codes.
5705211-C

Advertisement

Table of Contents
loading