Table 4-7. Host port commands (Continued)
Command
Description
• Byte 11 represents process status
219 (cont'd)
• Byte 12 represents process status
• Bytes 13-16 represent the frequency
• Bytes 17 and 18 represent the generator
• Bytes 19 and 20 represent the generator
4-32
information:
4 0 = Center frequency
4 1 = Set point unscaled
4 2 = Wide bus voltage test
4 3 = Water valve is off
4 4 = In diagnostic mode
4 5 = RF request
4 6 = Digital frequency display
4 7 = Continuous load power tuning
information:
4 0 = At set point
4 1 = Datalogging enabled
4 2 = RF enabled without interlock
4 3 = Heartbeat time-out off
value in Hertz.
4 For example, 2000000 (2,000,000 Hz)
real gamma.
4 For example, 250 (0.250, decimal is
implied)
actual VSWR.
4 For example, 1330 (1.330, decimal is
implied)
Communication Interfaces
Number of
Number of
Host Data
Response
Bytes
Data Bytes
(cont'd)