Ae Bus (Host) Port Transmission Parameters; Table 4-4. Baud Rate For Host Port; Table 4-5. Transmission Parameters - Advanced Energy HFV 8000 User Manual

Table of Contents

Advertisement

®
Advanced Energy
Use A4 to A0 (straight binary representation) to select Host port addresses 1 to 31.
Use BR1 and BR0 to define baud rate selection (see also

Table 4-4. Baud rate for Host port

BR1
Closed
Closed
Open
Open
Note 1
Requires internal modification to the unit. Contact Global Customer Support
before removing the safety cover (see
page 6-10

AE Bus (Host) Port Transmission Parameters

The communications capability of the serial AE Bus Host port is limited to the
following parameters:
• Start bits: One
• Number of Data Bits: 8
• Parity: Odd
• Stop bits: One
• Low-order bytes transmitted before high-order bytes.
Table 4-5
lists the Host port transmission parameters.

Table 4-5. Transmission parameters

Baud rate
(user
selectable)
Connector
pins
4-12
BR0
RS-232 (switch 8
open) Baud Rate
Closed
1200
Open
4800
Closed
9600
Open
19.2 K
).
RS-232
1200, 4800, 9600,
19.2 K
2, 3, 5
Communication Interfaces
Table
4-4).
RS-485/422 (switch 8
closed) Baud Rate
9600
19.2 K
38.4 K
57.6 K
"AE Global Customer Support" on
RS-485
9600, 19.2 K,
9600, 19.2 K,
38.4 K, 57.6 K
38.4 K, 57.6 K
5, 6, 7
Internal jumper
Note 1
RS-422
5705211-C