Table 4-7. Host port commands (Continued)
Command
Description
Reports a snapshot of generator data. The
219
controller board returns 21 data bytes:
report
condensed
• Bytes 0 and 1 represent forward power
snapshot of
• Bytes 2 and 3 represent reflected power
generator
data
• Bytes 4 and 5 represent delivered power
• Bytes 6 and 7 represent the set point
• Byte 8 represents the regulation mode:
• Byte 9 represents process status
• Byte 10 represents process status
5705211-C
4 2 = Forward power regulation
4 3 = Load power regulation
information:
4 0 = Power failure
4 1 = Unassigned interrupt has occurred
4 2 = A/D conversion failure
4 3 = Output on
4 4 = Load power regulation
4 5 = Overtemperature
4 6 = Interlock
4 7 = Line fault
information:
4 0 = Divide error
4 1 = Software single step
4 2 = Breakpoint
4 3 = Overflow
4 4 = Array bounds exception
4 5 = Undefined opcode
4 6 = Escape opcode exception
4 7 = Numeric coprocessor exception
Communication Interfaces
HFV 8000 Generator
Number of
Number of
Host Data
Response
Bytes
Data Bytes
0
21
4-31