Table 4-7. Host port commands (Continued)
Command
Description
• Byte 16 = Bus sample test
240
(continued)
report last
diagnostic
test data
• Bytes 17 and 18 = The Bus sample value
• Byte 19 = +10 V reference test
• Bytes 20 and 21 = The +10 V reference
• Byte 22 = Ground test
• Bytes 23 and 24 = The ground value at
• Byte 25 = I inverter test
• Bytes 26 and 27 = The I inverter value at
• Byte 28 = V inverter test
• Bytes 29 and 30 = The V inverter value
• Byte 31 = Dissipation test
• Bytes 32 and 33 = The dissipation value
5705211-C
4 0 = The value is in range
4 1 = The value is out of nominal
operating parameters
at the time of the test
4 0 = The value is in range
4 1 = The value is out of nominal
operating parameters
value at the time of the test
4 0 = The value is in range
4 1 = The value is out of nominal
operating parameters
the time of the test
4 0 = The value is in range
4 1 = The value is out of nominal
operating parameters
the time of the test
4 0 = The value is in range
4 1 = The value is out of nominal
operating parameters
at the time of the test
4 0 = The value is in range
4 1 = The value is out of nominal
operating parameters
at the time of the test
Communication Interfaces
HFV 8000 Generator
Number of
Number of
Host Data
Response
Bytes
Data Bytes
0
48
4-35