Tuning gain
This parameter affects the size of the tuning steps; the larger the number, the greater the
size of the tuning steps. (See
Note: When setting the tuning gain, be aware that if the gain is set too low, the tuning
function may react to noise in the signal and fail to correct the real direction of
change.
Tuning goal
When the tuning parameter measurement is below the tuning goal value, the generator
does not adjust the output frequency. (See
Note: This option of generator does not have the continuous tuning in load power
regulation enabled. For power regulation mode, the generator will tune until a
minimum tuning parameter is found. It then operates at that output frequency until
the RF enable command is turned off, then back on (through the Generator User
port on the HFV unit).
V
Virtual Front Panel (VFP) software
To order VFP, contact AE Worldwide Customer Service (see
Support" on page
W
Water solenoid
The optional water solenoid provides water flow control. If your generator has this
option, the valve controlling water flow opens during RF power delivery and closes
30 minutes after the last RF off command. To order the optional solenoid, contact AE
Worldwide Customer Service (see
5705211-C
Table
4-7, command 15, tuning gain.)
6-10).
"AE Global Customer Support" on page
Table
4-7, command 14, tuning goal.)
"AE Global Customer
HFV 8000 Generator
6-10).
iii