Table 4-7. Host port commands (Continued)
Command
Description
Reads the set point value. The controller
164
board returns three data bytes:
report
set point
• Bytes 1 and 2 represent the set point
• Byte 3 indicates the regulation mode:
Set with command 12.
Reads the AC On total time. The controller
195
board returns four data bytes, each count
report AC On
total time
equal to 0.25 h.
• For example, 11358 = 2839.5 h
Reads the RF On total time. The controller
196
board returns 4 data bytes, each count equal
report RF On
total time
to 0.25 h.
• For example, 10235 = 2558.75 h
Reads the total kilowatt-hours delivered. The
197
controller board returns four data bytes, each
report
kilowatt-
count equal to 0.25 kWh.
hours
• For example, 37581 = 9395.25 kWh
delivered
Reads the generator software revision level.
198
The controller board returns three ASCII
report
software
characters:
level
• One letter, followed by a two-digit
4-28
value in watts
4 Maximum power is 8000 W.
4 2 = Forward power regulation
4 3= Load power regulation
number
Communication Interfaces
Number of
Number of
Host Data
Response
Bytes
Data Bytes
0
3
0
4
0
4
0
4
0
3 ASCII
characters
5705211-C