Advanced Energy HFV 8000 User Manual page 58

Table of Contents

Advertisement

®
Advanced Energy
Table 4-7. Host port commands (Continued)
Command
Description
Specifies the desired goal that the tuning
14
algorithm will attempt to achieve. Send two
tuning goal
bytes, least significant byte first, representing
the desired goal.
• Range is 1 to 8000
Read back with command 153. See also
"Tuning goal" on page
Specifies the gain used in the tuning
15
algorithm. Send two bytes, least significant
tuning gain
byte first, representing the tuning gain.
• Accepts a value of 1 to 1000
Read back with command 154. See also
"Tuning gain" on page
Specifies the maximum frequency delta for
16
the tuning algorithm. Send four bytes, least
tuning delta
limits
significant byte first, representing the tuning
delta limit.
• Accepts a value of 1 to 100000
Read back with command 155. See also
"Tuning delta limit (Hz)" on page
Specifies the frequency step size for the scan
19
algorithm. Send four bytes, least significant
scan delta
byte first, representing the scan delta in Hertz.
• Accepts a value of 1 to 10000 (1 to
Read back with command 156. See also
"Scan delta frequency (Hz)" on page
Specifies the threshold at which the scan
20
algorithm completes. Send two bytes, least
scan
threshold
significant byte first, representing the scan
threshold.
• Accepts a value of 1 to 8000
Read back with command 157. See also
"Scan threshold" on page
4-22
5-15.
5-15.
10000 Hz).
5-16.
Communication Interfaces
Number of
Host Data
Bytes
2
2
4
5-15.
4
5-15.
2
Number of
Response
Data Bytes
1
CSR only
1
CSR only
1
CSR only
1
CSR only
1
CSR only
5705211-C