Advanced Energy
Frequency limits
The frequency limits parameter sets the range of frequencies over which the HFV unit
will operate. You can set a start frequency, an upper frequency limit, and a lower
frequency limit. (See
frequency, and starting frequency.)
In center frequency mode, all three frequencies are set to the center frequency. In
automatic tuning mode, the HFV unit starts searching for a tune at the start frequency
and sweeps up until a satisfactory tuning is found or until the upper frequency limit is
reached. If a tune is not found, this pattern is repeated.
Frequency rate of change
The frequency rate of change parameter defines how quickly the generator moves
through the steps during both the scanning and the tuning phase, in milliseconds. For
example, if you set this value to 5, the generator will make tuning adjustments no more
than every 5 ms. (See
L
LCD
Liquid crystal display. The actual display on the front panel.
S
Scan delta frequency
This parameter sets the maximum amount of frequency change for each step during
scanning. The typical value is 10,000. (See
frequency.)
Scan Threshold
The scan threshold parameter sets a threshold below which the tuning phase begins. If
the scan threshold is set too high, the generator will begin to tune too early and the
tuning will not be optimal. If the scan threshold is set too low, the threshold may never
be reached and automatic tuning will not take over. (See
threshold.)
T
TDS
Total dissolved solids.
Tuning delta limit
This parameter sets the maximum amount of frequency change for each step during
tuning. (See
Table
Note: When setting the tuning delta limit, be aware that if the limit is set too low, the
tuning function may react to noise in the signal and fail to correct the real
direction of change. The lowest recommended tuning delta limit value is 5000.
ii
Table
4-7, commands 3, 4, and 5, minimum frequency, maximum
Table
4-7, command 11, frequency rate of change.)
4-7, command 16, tuning delta limits.)
Table
4-7, command 19, scan delta
Table
4-7, command 20, scan
5705211-C