Table 4-25. Assembly Object Instance 100 Attributes; Table 4-26. Assembly Object Instance 101 Attributes - Advanced Energy HFV 8000 User Manual

Table of Contents

Advertisement

®
Advanced Energy

Table 4-25. Assembly object instance 100 attributes

Attribute
3

Table 4-26. Assembly object instance 101 attributes

Attribute
3
Note 1: Forward power sense expressed in 12 bit A/D units with upper 4 bits = 0.
Note 2: Reflected power sense expressed in 12 bit A/D units with the upper 4 bits = 0.
Note 3: Status byte bit flags are defined as:
• Bit 0 = POS (power on/off status)
4 0 = Power off
4 1 = Power On
• Bit 1 = SPS (set point status)
4 0 = Not at setpoint
4 1 = At setpoint
• Bit 2 = TS (temperature status)
4 0 = Not at overtemperature
4 1 = Overtemperature
• Bit 3 = Unused
• Bit 4 = INTS (interlock status)
4 0 = Interlock not satisfied
4 1 = Interlock satisfied
• Bits 5 through 7 = Unused
4-48
Access
Name
Get
Data
Forward Power
Reflected Power
Not used
Not used
Status
Access
Name
Get/Set
Data
Power Output Setpt.
Not Used
Power On Off
Communication Interfaces
Type
Value
STRUCT of
UINT
Note 1 below
UINT
Note 2 below
UINT
UINT
USINT
Note 3 below
Type
Value
STRUCT of
UINT
Note 4 below
UINT
USINT
Note 5 below
5705211-C

Advertisement

Table of Contents
loading

Table of Contents