INDUSTRY GUIDELINES

Table 1-3. Industry guidelines

Guideline
SEMI F47-
0200
SEMI S2-0200
*The power regulation folds back during a voltage sag event, then self-recovers.
This device must be installed and used only in compliance with the standards listed in
addition to VDE 0113, EN 60204 (IEC 204), and applicable requirements.

Conditions of Use

To comply with the stated directives and standards, you must meet the following
conditions of use:
• This device must be used in an overvoltage category II installation only.
• Before making any other connection, connect the auxiliary Protective Earth
ground conductor on the rear panel.
• Use only a shielded power cable on the output power connector.
• Install and operate this device only in a pollution degree 2 or better environment,
which means an indoor location such as a computer room, office, or factory floor
where only nonconductive pollution occurs during operation. Occasionally, a
temporary conductivity caused by condensation occurs when the device is not
operating.
• Nonstandard connectors for input/output power must be inaccessible to the user.
• Use only shielded cables on control, interface, and communication connectors.

INTERLOCKS

Advanced Energy Industries, Inc. products may include interlocks. When
interlocks exist, they are not intended for the protection of the operator,
but are intended to prevent damage to equipment or property. Hazardous
areas of Advanced Energy products are not operator accessible; the use
of a tool is required.
1-6
Specification for Semiconductor Processing Equipment Voltage
Sag Immunity*
Environmental, health, and safety guidelines for semiconductor
manufacturing equipment
Safety and Product Compliance Guidelines