Advanced Energy HFV 8000 User Manual page 65

Table of Contents

Advertisement

Table 4-7. Host port commands (Continued)
Command
Description
Requests analog voltages from diagnostic
199
analog to digital converter. Send one data
report
diagnosis
byte as follows:
status
• 0 = Forward power
• 1 = Reflected power
• 2 = Inverter power
• 3 = Fast I
• 4 = PAED
• 5 = Bus sample
• 6 = 10 V ref
• 7 = Ground
• 10 = I inverter
• 11 = V inverter
• 12 = Dissipation
• 13 = +15 V supply
• 14 = 10 V reference
• 15 = +30 V supply
• 16 = -15 V supply
• 17 = User set point analog
The controller board returns two bytes
representing the requested voltage value.
Reads the logic software checksum.
200
report
software
checksum
Reads the software configuration ID string.
201
The controller board returns a 32-byte ASCII
report
software
string representing the initial seven digits of
configuration
the AE part number, revision, and device
ID
description.
Reads MAC ID of DeviceNet interface. The
202
controller board returns one data byte
report
DeviceNet
representing the ID.
MAC ID
Note: If the DeviceNet is not installed or
5705211-C
powered, the response data byte will be
255.
Communication Interfaces
HFV 8000 Generator
Number of
Number of
Host Data
Response
Bytes
Data Bytes
1
2
0
2
0
32-byte
ASCII string
0
1
4-29

Advertisement

Table of Contents
loading

Table of Contents