Industries, Inc. All Rights Reserved. DISCLAIMER AND LIMITATION OF LIABILITY The information contained in this manual is subject to change by Advanced Energy Industries, Inc. without prior notice. Advanced Energy Industries, Inc. makes no warranty of any kind whatsoever, either expressed or implied, with respect to the information contained herein.
Page 5
Windows ® CUSTOMER FEEDBACK Advanced Energy's technical writing staff has carefully developed this manual using research-based document design principles. However, improvement is ongoing, and the writing staff welcomes and appreciates customer feedback. Please send any comments on the content, organization, or format of this user manual to: •...
AE VarioMatch Match Network, VM 1000/1500 Platform Table of Contents Chapter 1. Safety and Product Compliance Guidelines Important Safety Information ......... 1-1 Danger, Warning, and Caution Boxes in the Manual ....... 1-1 Safety Guidelines ..........1-2 Rules for Safe Installation and Operation ......1-2 Interpreting Product Labels ........
Page 8
Advanced Energy ® Chapter 4. Communication Interfaces and Controls 15-Pin VarioMatch Match Interface ........4-1 INTERFACE Connector ......... 4-1 Match Interface Cabling Requirements ......4-2 Pin Descriptions ..........4-2 Wiring Diagrams ..........4-4 Match INTERFACE Using Switches ........ 4-7 Chapter 5. Installation, Setup, and Operation Preparing to Install the VarioMatch Match Network ......
Page 9
External Load Checks - Open/Short RF Output Path ....6-3 Contacting AE Global Services ........6-4 Advanced Energy World Headquarters, 24 x 7 Technical Support ..6-4 Returning Units for Repair ........... 6-5 Chapter 7.
Page 10
Advanced Energy ® Table of Contents 57020080-00D...
Page 11
AE VarioMatch Match Network, VM 1000/1500 Platform List of Tables Table 2-1. Theory of operation description ........2-3 Table 2-2. Load capacitor capacity by load ........2-6 Table 3-1. Physical specifications ......... 3-7 Table 3-2. Electrical specifications for VM 300 series ......3-11 Table 3-3.
Page 12
Advanced Energy ® List of Tabl 57020080-00D...
Page 13
AE VarioMatch Match Network, VM 1000/1500 Platform List of Figures Figure 2-1. Theory of operation ........... 2-3 Figure 2-2. L match network circuit ........2-5 Figure 2-3. VarioMatch L match network circuit ......2-5 Figure 2-4. Gamma topology ..........2-7 Figure 2-5.
Page 14
Advanced Energy ® Figure 7-2. Tune coil, 14 turns: tap 1; Load coil, 3 turns: tap A ....7-3 Figure 7-3. Tune coil, 14 turns: tap Load coil, 3 turns: tap A ....7-4 Figure 7-4. Tune coil, 14 turns: tap 3; Load coil, 3 turns: tap A ....7-5 Figure 7-5.
Page 15
AE VarioMatch Match Network, VM 1000/1500 Platform 4 turns: tap B ..7-50 Figure 7-49. 4 MHz; Tune coil, 25 turns: tap 4; Load coil, Figure 7-50. 4 MHz; Tune coil, 25 turns: tap 5; Load coil, 4 turns: tap B ..7-51 Figure 7-51.
Guidelines IMPORTANT SAFETY INFORMATION To ensure safe installation and operation of the Advanced Energy V arioMatch match ® network, read and understand this manual before attempting to install and operate this unit. At a minimum, read and follow the safety instructions and practices documented under "Safety Guidelines"...
Advanced Energy ® ,&CAUTION: CAUTION indicates a potentially hazardous situation that, if not avoided, could result in minor or moderate injury, and/or damage to property. CAUTION is also used for property-damage-only accidents. SAFETY GUIDELINES Review the following information before attempting to install and operate the product.
AE VarioMatch Match Network, VM 1000/1500 Platform CE label � 1020 Protective Earth Ground 1029 Further information found in this guide. � & High voltage 1028 PRODU CT COMPLIA NCE The following sections include information about unit compliance and certification, including the conditions of use required to be in compliance with the standards and directives.
Advanced Energy ® Safety and Compliance Directives and Standards Certain options of this unit have been tested for and comply with the following electromagnetic compatibility (EMC) and safety directives and standards and industry guidelines. Note: This device must be installed and used only in compliance with the directives and standards listed in addition to EN 60204 (IEC 60204) and applicable requirements.
AE VarioMatch Match Network, VM 1000/1500 Platform Safety requirements for electrical equipment for measurement, control, and laboratory use INDUSTRY GUIDELINES • SEMI S2-0706 Environmental, Health, and Safety Guidelines for Semiconductor Manufacturing Equipment Conditions of Use To comply with the stated directives and standards, you must meet the following conditions of use: •...
Page 22
® INTERLOC KS AND LIMITS &_W ARNING: Advanced Energy® products only include interlocks when required by product specification. Interlocks in AE products are not intended to meet or satisfy safety requirements. Where interlocks exist, you must still meet and satisfy safety requirements. The presence of interlocks does not imply operator protection.
AE Vario Match™ Match Network, VM 1 000/1500 Platform Product Overview and Theory This chapter describes the AE VarioMatch Match Network, VM 1000/1500 ™ Platform, including its theory of operation. PRODU CT DESCRIPTION A match network transforms the impedance of the load to 50 Q to avoid reflected power and to ensure that the generator's full power is delivered to the load.
MAINS INTERFACE Advanced Energy ® A DC bias measurement circuit (available on most units) permits the DC self bias voltage created in the load to be monitored. The bias voltage is scaled down by a factor of :400 (if not otherwise stated) to a safe, convenient value. The DC bias test voltage delivered by the VarioMatch match network always is positive, even if the actual self bias voltage in the chamber is negative.
AE VarioMatch Match Network, VM 1000/1500 Platform THEORY OF OPERATION Figure 2-1 describes the VarioMatch match network's theory of operation. �----+- - - - - - - - - - - - - - - - - - , DC Bias Phase/ RF In Magnitude...
Page 26
Advanced Energy ® Table 2-1. Theory of operation description Description Section Motor Control The Motor Control section generates the signals needed to drive the capacitor motors using the phase and magnitude signals, and provides for the manual control interface. The motors are DC motors and use potentiometers to provide feedback as to the capacitor positions.
AE VarioMatch Match Network, VM 1000/1500 Platform L Match Topology Figure 2-1 shows a basic L match network circuit. 50 Ohms Load RF-Generator Impedance Series (Tune) Coil (Plasma) Shunt (Load) Capacitor 3260 Figure 2-2. L match network circuit The L match network received its name because of the configuration of the capacitor and coil used.
Advanced Energy ® The major practical problem of the L match network is the need for very large tuning capacitors when matching low impedances - a typical situation with plasma chambers. The following table provides an idea of the load capacitor's capacity. The...
AE VarioMatch Match Network, VM 1 000/1 500 Platform In configuration A (Gamma topology) the tune (series) capacitor comes first from the generator's point of view while in configuration B (L match topology) the load (shunt) capacitor comes first. 3430 Gamma topology Figure 2-4.
Page 30
Advanced Energy ® Product Overview and T heory 57020080-00D...
AE Vario Match™ Match Network, VM 1000/1500 Platform Specifications This chapter lists specifications for the V arioMatch match network. PHYSICAL S PECIFICATIONS Unit Dimensions Figure 3-1 through Figure 3-4 illustrate the physical dimensions. The PLASMA/LOAD connector can be located on either the rear panel or the bottom panel, depending on your model.
AE VarioMatch Match Network, VM 1000/1500 Platform GROUND 32.00 mm 1.26" .50 mm 0.87 " .50 m ·� 3269 7.58" 7.50 mm 8.56" · - --< -i Figure 3-3. VM 1000/1500 platform rear panel 57020080-00D Specifications...
Page 34
Advanced Energy ® i---------- 244.00 mm ________ _ ..__ 9.61" 230.00 mm --------- ----------- 9.06 " ________ 182.00 mm _______ -t 7.17" 62.00 mm 2.44" 14.00 mm 0.5 5 " 14.00 mm 0.55" Holes mounting the unit ground connection 254.00 mm 10.00"...
AE VarioMatch Match Network, VM 1000/1500 Platform 3275 Figure 3-5. VM 1000/1500 platform top panel Spacing Requirements The following sections describe the space needed to provide room for connections and to meet cooling requirements. 57020080-00D Specifications...
RF Input RF Input RF Input PLASMA/LOAD PLASMA/LOAD PLASMA/LOAD Advanced Energy ® FRONT PANEL CONNECTIONS For front panel and other connections: • 200 mm (7 .9") required for the connector when using a straight connector • 100 mm (3.9") required for the...
AE VarioMatch Match Network, VM 1000/1500 Platform Physical Specifications Table Table 3-1 describes the physical specifications of the V arioMatch match network. Physical specifications Table 3-1. Description Specification Mounting Directly onto the load or onto a mounting plate. See "Installing the VarioMatch Match Network" on page 5-4.
Page 38
AC power input (AC- IEC 320 connector MAINS) connector Coolant connectors Brass water fittings for water tubing 6 mm OD / 4 mm ID (0.24" OD/ 0.16" ID) Advanced Energy ® Table 3-1. Physical specifications (Continued ) Description Specification PLASMA/LOAD Internal coil specifications...
AE VarioMatch Match Network, VM 1000/1500 Platform Physical specifications (Continued) Table 3-1. Description Specification Tune coil The tune coil varies by part number on the number of turns, the number of possible taps, and the default tap setting from the factory. PN 69000001: 2.5 turns, fixed coil PN 69000036, 690001 16: 14 turns, taps at 4, 6, 8, 10, 12, 14 turns, default tap setting on 1...
Page 40
Gamma (Default: Gamma) PN 69000001: Gamma All other PNs: L match This section includes electrical specifications for VM 300, 700, VM 1000, and VM 1500 products. Advanced Energy ® Table 3-1. Physical specifications (Continued) Description Specification ELECTRICAL S PECIFICATIONS 3-10...
AE VarioMatch Match Network, VM 1000/1500 Platform VM 300 Series Table 3-2 describes the VM 300 series electrical specifications. Electrical specifications for VM 300 series Table 3-2. Description Specification Frequency 13.56 MHz 100 VAC to 240 V AC, single � AC line voltage AC line frequency 50 Hz to 60 Hz...
Advanced Energy ® Electrical specifications for VM 700 series (Continued ) Table 3-3. Description Specification Maximum RF load current 15 A Maximum RF load voltage 4000 p eak Input impedance to generator 5 0 Q Maximum load DC self bias...
AE VarioMatch Match Network, VM 1000/1500 Platform Table 3-4. Electrical specifications for VM 1000 series (Continued ) Description Specification o voe Maximum load DC self bias to 4000 voltage DC seltbias monitor voltage O V to l O V Runtime from start point to end 3 seconds point Tuning range...
Advanced Energy ® Electrical specifications for VM 1500 series (Continued ) Table 3-5. Description Specification Maximum reactive power Varies by V arioMatch product part number: PN 69000070, 69000226: 80,000 W PN 69000062: 100,000 W PN 69000001, 69000024, 69000025, 69000229, 69001207, 69001214, 69002207, 69002208: 140,000 W...
AE VarioMatch Match Network, VM 1000/1500 Platform ,&CAUTION: Do not use de-ionized water for cooling purposes. De-ionized water causes both corrosion and erosion of cooling manifolds. Cooling specifications Table 3-6. Description Specification Cooling medium Air-cooled (for units that show only "A" after the model name or Air- and Water-cooled (for units that show "W"...
Page 46
Advanced Energy ® Cooling specifications (Continued) Table 3-6. Description Specification Contaminates AE recommends the following specifications for the water used to cool the Navigator match network: • pH between 7 and 9 • total chlorine <20 ppm • total nitrate <10 ppm •...
AE VarioMatch Match Network, VM 1000/1500 Platform ENVIRONMENTAL S PECIFICATIONS Table 3-7 Table 3-8 describe the environmental specifications of the V arioMatch match network. Table 3-7. Climatic specifications (per EN50178) Temperature Relative Humidity Air Pressure Not e C to +40 °...
Page 48
Advanced Energy ® 3-18 Specifications 57020080-00D...
INTERFACE INTERFACE. INTERFACE AE Vario Match™ Match Network, VM 1000/1500 Platform Communication Interfaces and Controls This chapter describes the V arioMatch match network's communication interface. 15-PIN VARIOMATCH MATCH INTERFACE The 15-pin match on the VarioMatch match network provides analog and digital signals for controlling and monitoring the unit. This interface allows manual tune, preset, and monitoring functionality for a VarioMatch match network by an AE generator, such as a CESAR.
Advanced Energy ® Match Interface Cabling Requirements INTERFACE Connect the VarioMatch match network's 15-pin port to the generator with a shielded, 15-wire 1/0 cable. Minimize signal losses by keeping the cable as short as possible. The maximum recommended cable length between the V arioMatch match network and the controller is 10 meters (33 feet), although this may vary by installation.
Page 51
AE VarioMatch Match Network, VM 1000/1500 Platform Table 4-1. VarioMatch match INTERFACE connector pin description Return Name Signal Description Type GROUND Reference ground for DC Bias and capacitor position signals. Reserved or 9 M ANUAL Input Connect this + 15 V input to ground to set the MODE...
MONITOR MATCHING Advanced Energy ® Table 4-1. VarioMatch match INTERFACE connector pin description Return Name Signal Description Type Output Shunt (load) capacitor position signal. C Lo POSITION The voltage at this output is directly proportional to the position of the capacitor ·...
Page 53
AE VarioMatch Match Network, VM 1000/1500 Platform User-supplied c i rcuitry Internal circuitry �-J may vary Figure 4-3. Pin 1 O User-suppl i ed circuitry Internal circuitry may vary � 3441 Figure 4-4. Pin 1 1 57020080-00D Communication Interfaces and Controls...
Page 54
Advanced Energy ® User�upplied circuitry Internal circuitry may vary 1 0 k Q 100 nF 1 kQ 12 -----., Figure 4-5. Pin 12 User- supplied circuitry Internal circu i try may vary 10 kQ $f------- G <21 f 100 ,F <2...
INTERFACE AE VarioMatch Match Network, VM 1000/1500 Platform Internal circu User supplied c i rcui!Jy may vary CD4001 B (NOR Gate) 9 1-- - ... Figure 4-7. Pin 15 Match INTERFACE Using Switches To construct a simple manual control, wire four normally open momentary switches for the motor drive and one on/off switch for auto/manual mode selection as described...
Page 56
Advanced Energy ® 4- 8 Communication Interfaces and Controls 57020080-00D...
AE Vario Match™ Match Network, VM 1000/1500 Platform Installation, Setup, and Operation PREPARING TO INSTALL THE VARIOMATCH MATCH NETWORK The following sections provide information that you need to understand before installing the V arioMatch match network. Spacing Requirements "Physical Specifications" on page 3-1 for the unit dimensions and clearance.
Unpacking Unpack and inspect the unit carefully, looking for obvious physical damage. If no damage is apparent, proceed with the installation. If you do see signs of shipping damage, contact Advanced Energy and the carrier immediately (see "Contacting AE ®...
AE VarioMatch Match Network, VM 1000/1500 Platform Cable Requirements GENERAL CABLING CONSIDERATIONS FOR PLASMA/LOAD The main objective of an RF delivery system is to provide as much of the generator's output power to the load as possible. However, losses occur in the coaxial cable, the match network, and in the lead between the match network and load.
PLASMA/LOAD Advanced Energy ® If your unit uses a coaxial connector, then wire the coaxial connector to the load using the shortest possible length of cable. For power levels greater than 1 kW cable length should not exceed one meter. Use a coaxial cable with high voltage capability and good thermal immunity.
_& CAUTION: AE VarioMatch Match Network, VM 1 000/1 500 Platform "Connecting the Match INTERFACE (Optional)" on page 5-7 "Connecting the Cooling Water" on page 5-7 "Connecting RF Input From a Generator" on page 5-8 "Connecting to the Load" on page 5-9 "Connecting AC Input (Mains) Power"...
Page 62
GROUND Advanced Energy ® A good ground connection is essential to achieve the best possible RF connection between the match network and the ground of the load. The V arioMatch match network chassis must be intimately grounded to the plasma chamber The ground lead must provide a low impedance RF path.
MAINS, PLASMA/LOAD, RF-GENERA TOR PLASMA/LOAD INTERFACE CAUTION: AE VarioMatch Match Network, VM 1000/1500 Platform When selecting the mounting hardware, choose screws that will not extend into the unit cabinet more than 10 mm. Brass fasteners are recommended . • Mounting plate {acts as ground) Figure 5-1.
GENERATOR connector on the match network. The RF-GENERATOR connector is a 50 Q N-type connector. RF-GENERATOR connector, and Advanced Energy ® ,&CAUTION: When fastening the water hose, be sure the bullkhead does not rotate; this could cause internal damage to the unit.
AE VarioMatch Match Network, VM 1000/1500 Platform 3280 N-type connector Figure 5-3. input connector pin descriptions T able 5-1. RF Description Center RF input Outer Ground Connecting to the Load Note: VM 69000082: The RF output connector is customer supplied. See your company's internal documentation for information.
AE VarioMatch Match Network, VM 1000/1500 Platform 6 mm brass tube fitting Figure 5-7. CONNECTING THE VARIOMATCH MATCH NETWORK TO THE LOAD To Connect the VarioMatch Match Network to the Load: 1. Review the cabling requirements in "Cable Requirements" on page 5-3.
Advanced Energy ® The AC input (Mains) connector is an IEC 320 connector. Figure 5-8 shows the input power connector, and Table 5-2 describes each pin. Input (Mains) connector Figure 5-8. Table 5-2. Input connector pin description Description Phase ( or neutral if pin 2 is...
Page 69
MAINS. MAINS AE VarioMatch Match Network, VM 1000/1500 Platform & DANGER: RISK OF DEATH OR BODILY INJURY. Disconnect and lockout/tagout all sources of input power before working on this unit or anything connected to it. & W ARNING: Leaving on the RF power after turning off the input power to the match network may damage the unit.
MAINS, MAINS MAINS Advanced Energy ® Services (see Chapter 6, ''Troubleshooting and Global Services"). d. Did reflected power decrease to within specifications? If not, ensure the capacitors are within the tuning range of 30 to 80%. e. Did the motors stop moving? If the motors do not stop moving, ensure the capacitors are within the tuning range of 30 to 80%.
Page 71
INTERFACE INTERFACE. AE VarioMatch Match Network, VM 1000/1500 Platform The second sensor is the phase detector, which measures the phase change compared to a perfect 50 resistive load. This sensor drives the tune variable capacitor which is in series with the coil. Both magnitude and phase information are fed to the motor drive electronics which immediately drive the electric motors in the correct direction.
MATCHING INTERFACE. Host Port Advanced Energy ® Interaction With a Cesar Generator You can control the V arioMatch match network in either manual mode or automatic mode using a Cesar generator. When the V arioMatch match network is connected to a...
Page 73
AE VarioMatch Match Network, VM 1000/1500 Platform &WARNING: Maintenance personnel must receive proper training before installing, troubleshooting, or maintaining high-energy electrical equipment. Potentially lethal voltages could cause death, serious personal injury, or damage to the equipment. Ensure that all appropriate safety precautions are taken.
Advanced Energy ® • You can configure some ICP units to use either the Gamma or the L match topology. See "Changing the Configuration Between the match and the Gamma Topology" on page 5 - If you purchased a unit with 2 MHz frequency, you can change additional fixed capacitors.
Page 75
MAINS. PLASMA/LOAD). AE VarioMatch Match Network, VM 1000/1500 Platform For specific recommendations, contact Global Services for a technical bulletin for your model. To Change the Tap Settings on the Tune Coil: 1. Turn off RF from the generator. 2. Disconnect AC 3.
Page 76
Advanced Energy ® 8. Using the wrench, screw the tap to the selected tum on the coil. Tune coil, tap position for small capacitive load PLASMNLOAD Tapping of the tune coil for small capacitive load Figure 5-9. 5-20 Installation, Setup, and Operation...
Page 77
AE VarioMatch Match Network, VM 1000/1500 Platform Tune coil, tap position for medium capac tive load PLASMNLOAD Figure Tapping of the tune coil for medium capacitive load 5-10. 57020080-00D Installation, Setup, and Operation 5-21...
Advanced Energy ® Tune coil, tap position for high capacitive load PLASMA/LOAD Figure 5-11. Tapping of the tune coil for high capacitive load 9. Reattach the top cover: a. Plug in the fan b. Attach the top cover using the twelve screws you removed in step 2.
Page 79
MAINS. (PLASMA/LOAD). AE VarioMatch Match Network, VM 1000/1500 Platform By changing the tap position on this coil, you can adjust the match range for the size of the load. The more coils that are active between the tap and the load capacitor, the higher the resulting capacitance.
Advanced Energy ® ---- RFGENERATOR connection ---- Load coil, tap position small loads Figure 5-12. Tap position for small loads 5- 24 Installation, Setup, and Operation 57020080-00D...
AE VarioMatch Match Network, VM 1000/1500 Platform �--- GENERATOR connection •◄ 1-- - - Load coil, tap position medium loads Tap position for medium loads Figure 5-13. 57020080-00D Installation, Setup, and Operation 5-25...
Advanced Energy ® RFGENERATOR connection - - - Load coil, position C for large loads Tap position for large loads Figure 5-14. 8. Reattach the top cover: a. Plug in the fan b. Attach the top cover using the twelve screws you removed in step 2.
AE VarioMatch Match Network, VM 1 000/1 500 Platform Changing the Configuration Between the L match and the Gamma Topology filW ARNING: Maintenance personnel must receive proper training before installing, troubleshooting, or maintaining high-energy electrical equipment. Potentially lethal voltages could cause death, serious personal injury, or damage to the equipment.
Advanced Energy ® • "Changing the Interconnector" on page 5-29 • "Changing the Jumpers" on page 5-32 • "Reattaching the Top Cover and Reconnecting Power and R ' on page 5-35 • Also see "Interaction With a Cesar Generator" on page 5-16...
Page 85
AE VarioMatch Match Network, VM 1000/1500 Platform CHANGING THE INTERCONNECTOR To Change the lnterconnector: 1. Locate the alternate interconnector and bridge. These two pieces were attached to the unit when shipped from the factory. lnterconnector Bridge Figure Alternate interconnector and bridge 5-15.
Page 86
Advanced Energy ® 6. Using a 7 mm wrench, unscrew the interconnection from it's current position. Step4 interconnector Step 3 Figure Disconnect the original interconnection 5-16. 7. Attach the bridge by screwing it onto the bracket with two 7 mm bolts.
Advanced Energy ® CHANGING THE JUMPERS To Change the Jumpers: 1. Remove the front panel by unscrewing the eleven screws as shown, then remove the front panel. Screws Figure 5-18. Remove the front panel 5-32 Installation, Setup, and Operation 57020080-00D...
Page 89
AE VarioMatch Match Network, VM 1000/1500 Platform 2. Carefully remove the three solder joints on the left box as shown, and remove the top of the box. Solder locations Remove solder joints Figure 5-19. 57020080-00D Installation, Setup, and Operation 5-33...
Advanced Energy ® 3. Move the jumpers as needed for the desired configuration (see Figure 5-20 on 5-35). page 5-34 Figure 5-21 on page Two jumpers on the left two posts for L topology Jumper setting for L match topology Figure 5-20.
AE VarioMatch Match Network, VM 1000/1500 Platform Two jumpers on the right two posts for Gamma-topology Figure 5-21. Jumper setting for Gamma topology 4. Replace the top cover of the metal box, carefully resoldering in place. 5. Replace the front panel by replacing the eleven screws. REA TT ACHING THE TOP COVER AND RECONNECTING POWER AND RF To Reattach the Top Cover and Reconnect Power and RF:...
Advanced Energy ® Changing the Fixed Capacitor Setting (Model 041 5 2 MHz Units Only) The V arioMatch match network Model 0415 2 MHz unit is equipped with a circuit board containing additional fixed capacitors You can switch these capacitors in parallel to the load capacitor to increase the capacitance.
AE VarioMatch Match Network, VM 1000/1500 Platform table shows the additional capacitance as a consequence of the jumper settings. Figure 5-22 shows the location of the circuit board and jumpers. Table 5-3. Capacitance due to jumper settings on circuit board Bridge Capacitance 0 pF...
Advanced Energy ® b. Attach the top cover using the twelve screws you removed in step 2. 8. Reconnect PLASMA/LOAD, RF-GENERATOR, and AC MAINS as described "Installing the VarioMatch Match Network" on page 5-4 DISCONNECTING WATER A ND DRAINING THE VARIOMATCH MATCH NETWORK Use this procedure when you need to purge the VarioMatch match network of cooling water for maintenance, moving, or storing.
Page 95
AE VarioMatch Match Network, VM 1000/1500 Platform For information to assist you in disconnecting the input power cable, see "Connecting AC Input (Mains) Power'' on page 5-11. 3. Disconnect the RF input connector. For information to assist you in this procedure, see "Connecting RF Input From a Generator"...
Page 96
Advanced Energy ® 5-40 Installation, Setup, and Operation 57020080-00D...
AE Vario Match™ Match Network, VM 1000/1500 Platform Troubleshooting and Global Services This chapter contains basic troubleshooting information, as well as procedures for returning a unit for repair. TROU BLESHOOTING OVERVIEW Before calling AE Global Services, consult the following sections and perform recommended checks and troubleshooting procedures.
Advanced Energy ® TROU BLESHOOTING CHEC KLISTS Use troubleshooting checklists to begin troubleshooting your unit. .&_ W ARNING: RISK OF DEATH OR BODILY INJURY. Disconnect all sources of input power before working on this unit or anything connected to it.
AE VarioMatch Match Network, VM 1000/1500 Platform TROU BLESHOOTING U NIT OUTPUT Use extreme caution as this section involves troubleshooting the output of the unit. .&_ W ARNING: RISK OF DEATH OR BODILY INJURY. Disconnect all sources of input power before working on this unit or anything connected to it. .&_ W ARNING: Operating and maintenance personnel must have the correct training...
When you call Global Services, make sure to have the unit serial number and part number. These numbers are available on unit labels. Advanced Energy World Headquarters, 24 x 7 Technical Support AE Global Services contact information Table 6-1. Office Contact...
AE VarioMatch Match Network, VM 1000/1500 Platform RETURNING U NITS FOR REPAIR Before returning any product for repair and/or adjustment, first follow all troubleshooting procedures. If, after following these procedures, you still have a problem, or if the procedure instructs you to, contact AE Global Services and discuss the problem with a representative.
Page 102
Advanced Energy ® Troubleshooting and Global Services 57020080-00D...
AE Vario Match™ Match Network, VM 1000/1500 Platform VarioMatch Match Network Tuning Ranges This chapter shows the V arioMatch match network's tuning ranges, using Smith charts. The figure captions include the number of turns and tap settings for the Smith chart shown in the illustration.
Advanced Energy ® Smith Charts T able 7-1. Location of Smith chart illustrations for 14-turn tune coil Tune Coil Load Coil Tap Setting Tap Setting Figure 7-2 Figure 7-8 Figure 7-14 Figure 7-3 Figure 7-9 Figure 7-15 Figure 7-4 Figure 7-10...
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-2. Tune coil, 14 turns: tap 1; Load coil, 3 turns: tap A 57020080-00D VarioMatch Match Network Tuning Ranges...
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-4. Tune coil, 14 turns: tap 3; Load coil, 3 turns: tap A 57020080-00D VarioMatch Match Network Tuning Ranges...
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-6. Tune coil, 14 turns: tap 5; Load coil, 3 turns: tap A 57020080-00D VarioMatch Match Network Tuning Ranges...
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-8. Tune coil, 14 turns: tap 1; Load coil, 3 turns: tap B 57020080-00D VarioMatch Match Network Tuning Ranges...
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-10. Tune coil, 14 turns: tap 3; Load coil, 3 turns: tap B 57020080-00D VarioMatch Match Network Tuning Ranges 7-11...
Page 114
Advanced Energy ® Figure 7-11. Tune coil, 14 turns: tap 4; Load coil, 3 turns: tap B 7-12 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 115
AE VarioMatch Match Network, VM 1000/1500 Platform Figure Tune coil, 14 turns: tap 5; Load coil, 3 turns: tap B 7-12. 57020080-00D VarioMatch Match Network Tuning Ranges 7-13...
Page 116
Advanced Energy ® Figure 7-13. Tune coil, 14 turns: tap 6; Load coil, 3 turns: tap B 7-14 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 117
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-14. Tune coil, 14 turns: tap 1; Load coil, 3 turns: tap C 57020080-00D VarioMatch Match Network Tuning Ranges 7-15...
Page 118
Advanced Energy ® Figure 7-15. Tune coil, 14 turns: tap 2; Load coil, 3 turns: tap C 7-16 VarioMatch Match Network Tuning Ranges 57020080-00D...
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-16. Tune coil, 14 turns: tap 3; Load coil, 3 turns: tap C 7-17 57020080-00D VarioMatch Match Network Tuning Ranges...
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-18. Tune coil, 14 turns: tap 5; Load coil, 3 turns: tap C 57020080-00D VarioMatch Match Network Tuning Ranges 7-19...
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 40 MHz; Tune coil, 6 turns: tap 6; 7-32. VM 041 5 Schematic The tune (series) coil has taps at taps at 10, 13, 16, 19, 22, and 25 turns. These are labeled through 6 in the schematic.
Advanced Energy ® "' �x - - i-- (\\ ' i RF IN t_t_r_t_t_t ___ _ mnttnfff 1 1 1 RF OUT Lout � � � Figure 7-33. VM 0415 coil and inductor schematic Smith Charts 2 MHZ UNITS The Smith charts for the 2 MHz VM 4015 show the tuning range with tune coil tap set at 6, load coil tap set at E.
Page 137
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-34. 2 MHz; Tune coil, 6; Load coil, E; O pF 57020080-00D VarioMatch Match Network Tuning Ranges 7-35...
Advanced Energy ® Figure 7-39. 2 MHz; Tune coil, 6; Load coil, E; 3400 pF 4 MHZ UNITS The Smith charts for the 4 MHz VM 4015 show the tuning range at each tune and load coil tap setting. AE does not recommend varying the additional capacitance setting.
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-44. 4 MHz; Tune coil, 25 turns: tap 5; Load coil, 4 turns: tap A 57020080-00D VarioMatch Match Network Tuning Ranges 7-45...
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-46. 4 MHz; Tune coil, 25 turns: tap 1; Load coil, 4 turns: tap B 57020080-00D VarioMatch Match Network Tuning Ranges 7-47...
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-48. 4 MHz; Tune coil, 25 turns: tap 3; Load coil, 4 turns: tap B 57020080-00D VarioMatch Match Network Tuning Ranges 7-49...
Page 152
Advanced Energy ® Figure 7-49. 4 MHz; Tune coil, 25 turns: tap 4; Load coil, 4 turns: tap B 7-50 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 153
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-50. 4 MHz; Tune coil, 25 turns: tap 5; Load coil, 4 turns: tap B 57020080-00D VarioMatch Match Network Tuning Ranges 7-51...
Page 154
Advanced Energy ® Figure 7-51. 4 MHz; Tune coil, 25 turns: tap 6; Load coil, 4 turns: tap B 7-52 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 155
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 4 MHz; Tune coil, 25 turns: tap 1; Load coil, 4 turns: tap C 7-52. 57020080-00D VarioMatch Match Network Tuning Ranges 7-53...
Page 156
Advanced Energy ® Figure 7-53. 4 MHz; Tune coil, 25 turns: tap 2; Load coil, 4 turns: tap C 7-54 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 157
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-54. 4 MHz; Tune coil, 25 turns: tap 3; Load coil, 4 turns: tap C 57020080-00D VarioMatch Match Network Tuning Ranges 7-55...
Page 158
Advanced Energy ® Figure 7-55. 4 MHz; Tune coil, 25 turns: tap 4; Load coil, 4 turns: tap C 7-56 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 159
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-56. 4 MHz; Tune coil, 25 turns: tap 5; Load coil, 4 turns: tap C 57020080-00D VarioMatch Match Network Tuning Ranges 7-57...
Page 160
Advanced Energy ® Figure 7-57. 4 MHz; Tune coil, 25 turns: tap 6; Load coil, 4 turns: tap C 7-58 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 161
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-58. 4 MHz; Tune coil, 25 turns: tap 1; Load coil, 4 turns: tap D 57020080-00D VarioMatch Match Network Tuning Ranges 7-59...
Page 162
Advanced Energy ® Figure 7-59. 4 MHz; Tune coil, 25 turns: tap 2; Load coil, 4 turns: tap D 7-60 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 163
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-60. 4 MHz; Tune coil, 25 turns: tap 3; Load coil, 4 turns: tap D 57020080-00D VarioMatch Match Network Tuning Ranges 7-61...
Page 164
Advanced Energy ® Figure 7-61. 4 MHz; Tune coil, 25 turns: tap 4; Load coil, 4 turns: tap D 7-62 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 165
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 4 MHz; Tune coil, 25 turns: tap 5; Load coil, 4 turns: tap D 7-62. 57020080-00D VarioMatch Match Network Tuning Ranges 7-63...
Page 166
Advanced Energy ® Figure 7-63. 4 MHz; Tune coil, 25 turns: tap 6; Load coil, 4 turns: tap D 7-64 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 167
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-64. 4 MHz; Tune coil, 25 turns: tap 1; Load coil, 4 turns: tap E 57020080-00D VarioMatch Match Network Tuning Ranges 7-65...
Page 168
Advanced Energy ® Figure 7-65. 4 MHz; Tune coil, 25 turns: tap 2; Load coil, 4 turns: tap E 7-66 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 169
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-66. 4 MHz; Tune coil, 25 turns: tap 3; Load coil, 4 turns: tap E 57020080-00D VarioMatch Match Network Tuning Ranges 7-67...
Page 170
Advanced Energy ® Figure 7-67. 4 MHz; Tune coil, 25 turns: tap 4; Load coil, 4 turns: tap E 7-68 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 171
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-68. 4 MHz; Tune coil, 25 turns: tap 5; Load coil, 4 turns: tap E 57020080-00D VarioMatch Match Network Tuning Ranges 7-69...
Page 172
Advanced Energy ® Figure 7-69. 4 MHz; Tune coil, 25 turns: tap 6; Load coil, 4 turns: tap E 7-70 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 173
RF IN RF OUT RF IN RF OUT AE VarioMatch Match Network, VM 1000/1500 Platform Schematics C selies Cslnmt Figure 7-70. /GP coil and inductor schematic, Gamma C seiies Csbunt Figure 7-71. /GP coil and inductor schematic, L match 57020080-00D VarioMatch Match Network Tuning Ranges 7-71...
AE VarioMatch Match Network, VM 1000/1500 Platform DELTA MATCH Schematic Cseries Lout (wire) RF IN RF OUT Cshunt Figure 7-75. Delta match coil and inductor schematic 57020080-00D VarioMatch Match Network Tuning Ranges 7-75...
Advanced Energy ® Smith Chart Figure 7-76. Tune coil, 2.5 turns VM PN 69000082 Schematic and Smith charts are not available. 7-76 VarioMatch Match Network Tuning Ranges 57020080-00D...
10 9 8 7 6 5 4 3 2 1 AE VarioMatch Match Network, VM 1000/1500 Platform VM 700 Schematic These units have one 10-turn tapped tune (series) coil and one 26.5-turn fixed coil. The tapped coil has taps on every tum, labeled 1 through 10 in the schematic. The load (shunt) coil has 3 turns, with taps labeled A, B, and C.
Advanced Energy ® Table 7-5. Location of Smith chart illustrations for VM 700 Tune Coil Load Coil Tap Setting Tap Setting Figure 7-84 Figure 7-85 Figure 7-86 Figure 7-87 Figure 7-78. Tune coil, 10 turns: tap 1; Load coil, 3 turns: tap A...
Page 181
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-79. Tune coil, 10 turns: tap 2; Load coil, 3 turns: tap A 57020080-00D VarioMatch Match Network Tuning Ranges 7-79...
AE VarioMatch Match Network, VM 1000/1500 Platform Tune coil, 1 O turns: tap 4; Load coil, 3 turns: tap A Figure 7-81. 57020080-00D VarioMatch Match Network Tuning Ranges 7-81...
Page 184
Advanced Energy ® Tune coil, 1 O turns: tap 5; Load coil, 3 turns: tap Figure 7-82. 7-82 VarioMatch Match Network Tuning Ranges 57020080-00D...
AE VarioMatch Match Network, VM 1000/1500 Platform Tune coil, 1 O turns: tap 6; Load coil, 3 turns: tap A Figure 7-83. 57020080-00D VarioMatch Match Network Tuning Ranges 7-83...
Advanced Energy ® Figure 7-84. Tune coil, 1 O turns: tap Load coil, 3 turns: tap A 7-84 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 187
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-85. Tune coil, 10 turns: tap 8; Load coil, 3 turns: tap A 57020080-00D VarioMatch Match Network Tuning Ranges 7-85...
Advanced Energy ® Tune coil, 1 O turns: tap 9; Load coil, 3 turns: tap A Figure 7-86. 7-86 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 189
AE VarioMatch Match Network, VM 1000/1500 Platform Figure 7-87. Tune coil, 10 turns: tap 10; Load coil, 3 turns: tap A 57020080-00D VarioMatch Match Network Tuning Ranges 7-87...
Page 190
Advanced Energy ® 7-88 VarioMatch Match Network Tuning Ranges 57020080-00D...
Page 191
AE VarioMatch Match Network, VM 1000/1500 Platform I ndex CESAR generator 4-1 cooling water 5-7 AC input 5-12 ground 5-5 connecting 5-11 match INTERFACE 5-7 connector pin description 5-12 PLASMA/LOAD 5-9 connector specifications 3-8 RF input from generator 5-8 current specifications 3-11, 3-12, 3-13 to CESAR generator 5-16 frequency specifications 3-11, 3-12, 3-13 to the load 5-11...
Page 192
Advanced Energy ® MAINS Gamma topology 2-6 general description 2-1 see also AC input ground 4-2, 5-5 connector 3-8, 5-12 guidelines manual tuning mode 5-15 marking, CE 1-3 safety 1-2 SEMI 1-5 maximum load DC selfb ias voltage 3-11, 3-12,...
Page 193
AE VarioMatch Match Network, VM 1000/1500 Platform input, cabling specifications 5-2 tuning range 3-11, 3-12, 3-13, 3-14 shiel ding 5-4 water contaminates 3-16 runtime from startpoint to endpoint 3-11, 3-12, water flow 3-15 3-13, 3-14 water pressure 3-15 water temperature 3-15 weight 3-7 standards 1-4 safety...
Page 194
Advanced Energy ® voltage AC input speci f ications 3-11, 3-12, 3-13 warranty authorized returns 6-5 water connecting 5-7 connectors 3-8 contaminants specification 3-16 flow specification 3-15 hose speci f icatinos 5-2 pressure specification 3-15 temperature speci f ication 3-15...