Table 4-7. Host port commands (Continued)
Command
Description
Reads the minimum frequency value. The
133
controller board returns four data bytes
report
minimum
representing the minimum frequency in
frequency
Hertz.
• Range is 1765000 to 2165000.
• For example, 2000000 (2,000,000 Hz)
Set with command 3.
Reads the maximum frequency value. The
134
controller board returns four data bytes
report
maximum
representing the maximum frequency value in
frequency
Hertz.
• Range is 1765000 to 2165000
• For example, 2000000 (2,000,000 Hz).
Set with command 4.
Reads the starting frequency value. The
135
controller board returns four data bytes
report
starting
representing the starting frequency in Hertz.
frequency
• Range is 1765000 to 2165000
• For example, 2000000 (2,000,000 Hz).
Set with command 5.
Reads the generator forward power. The
136
controller board returns two data bytes
report
forward
representing the value in watts.
power
• For example, 2500 (2500 W)
Reads the generator reflected power. The
137
controller board returns two data bytes
report
reflected
representing the reflected power value in
power
watts.
• For example, 2500 (2500 W)
Reads the host port time-out value. The
140
controller board returns two data bytes
Host port
time-out
representing the time-out value in seconds.
value
• For example, 500 (5.00 s, decimal is
Set with command 40.
4-24
implied)
Communication Interfaces
Number of
Number of
Host Data
Response
Bytes
Data Bytes
0
4
0
4
0
4
0
2
0
2
0
2
5705211-C