Scan threshold
The scan threshold sets a threshold below which the tuning phase begins.
If the scan threshold is set too high, the generator will begin to tune too early and the
tuning will not be optimal. If the scan threshold is set too low, the threshold may never
be reached and automatic tuning will not take over. (See
threshold.)

Display Mode and the LCD Display Indicator

The Display Mode front panel push button allows you to cycle through modes 1, 2, 3,
4, and 5.
To select a mode:
1. Scroll through the menu to the desired mode.
2. Press and hold the Display Mode button for five seconds. The mode will change,
and the indicator will display the state.
Note: FAULT automatically displays when a fault condition occurs. If the display
mode switch is not pressed for five minutes, the display returns to MODE 1
unless a fault has occurred. In that case, FAULT displays until you press the
Display Mode button.
The modes represent the following:
• MODE 1 (default)
Top line—displays current forward and reflected power
Bottom line—displays set point power and output frequency
• MODE 2
Top line—displays Total Hours AC On, Total hours RF On
Bottom line—displays Total kWh delivered
• MODE 3
Top line—displays: Press and Hold
Bottom line—displays: Center/Auto Tune
Note: A flashing LOAD REG indicator means the generator is in center
frequency mode; if the LOAD REG is not flashing, the generator is
automatic tune mode.
• MODE 4
Top line—displays: Press and Hold
Bottom line—displays output frequency selection; top, side, full, or custom band
5-16
Installation, Setup, and Operation
Table
4-7, command 20, scan
5705211-C