To connect the cooling water, complete the following steps:
1. Connect the input and output water connections and tighten securely.
2. If you do not have an optional water solenoid, install the water shield.
3. Turn on the water and ensure that there are no leaks.
4. Ensure the flow rate and temperature are within the minimum specifications
required to operate the HFV generator (see
page 3-1
Note: Keep the water-cooling system running as long as the rear circuit breaker is on
to help maximize the cooling of the auxilliary supply, which is also water-
cooled.
If your generator does not include the water solenoid, be sure the water
shield is installed.

Connecting I/O and Auxiliary Connectors

RISK OF DEATH OR BODILY INJURY
Disconnect and lockout/tagout all sources of input power before working
on this unit or anything connected to it.
Do not connect any power to this unit without first connecting cooling
water and ensuring that there are no leaks.
Connect and secure all interface connectors as well as any auxiliary connectors. See
"Interconnect Schematics" on page 4-7
5-6
and
"Environmental Specifications" on page
Installation, Setup, and Operation
"Functional Specifications" on
3-8).
for interface circuitry electrical diagrams.
5705211-C