4.3.3 Adjustment of the Station Height

 Outline
Adjust the height of the station.
 Procedure
hexagon socket head screw x3
Tighten after
adjusting
© 2014 MIMAKI ENGINEERING CO.,LTD.
CA base
1. Remove the Cover R, Cover R2 and Undercover R.
2. Loosen the 4 screws used for CA base adjustment.
Loosen x4
3. Loosen the hexagon socket head screws (x3) and make an
Adjust by rotate x3
adjustment to set their thickness gauge at 5 mm, then tighten the
nuts.
4. Tighten up 4 loosened screws used for CA base adjustment
5mm
F/W ver.
1.00
Remark
Rev.
1.0
1
2
3
4
5
6
7
8
4.3.3
R.1.0
P.1