3.1.7 Replacement of the Cap Head Assy.

 List of replacement procedures
Item
Covers
Removal of covers, etc.
1.
Cap Assy
Removal of the Cap Assy.
2.
Mounting of the Cap Assy.
3.
Adjustment of Capping
4.
Check
Cleaning operation
5.
Covers
Mounting of the covers.
6.
Be sure to wear protective glasses and working gloves during the operation.
Ink may get into your eyes depending on the working condition, or hand skin may get rough if you touch
the ink.
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
© 2014 MIMAKI ENGINEERING CO.,LTD.
Work operation
Remove the Front cover M, L and under cover R.
Remove the Cap Assy.
Attach the Cap Assy while pushing it toward you.
Carry out "CAPPING" (by using the key) [# ADJUST].
Check whether each assembly and adjustment has been
carried out properly.
Mount the covers that have been removed.
F/W ver.
1.00
Remark
Cap head Assy.
Description
CAPPING POS: the cap slider is located at 3 mm to the
right from the uppermost point it has
reached on the cap base3 mm to the right
from the uppermost position of the cap
slider.
AirPullPOS.:
the clearance between the head and
uppermost point of the cap is set at 0.5
mm.
FlushingPOS:
the clearance between the head and
uppermost point of the cap is set at 1
mm.