Concerning Errors And Malfunctions; Rough Identification Of The Source Of The Trouble - MIMAKI JV300-130 Maintenance Manual

Hide thumbs Also See for JV300-130:
Table of Contents

Advertisement

MAINTENANCE MANUAL > Troubleshooting > Details on Errors and Malfunctions > Concerning Errors and Malfunctions
Model
JV300-130/160
Issued 2014.05.30 Revised

7.1.1 Concerning Errors and Malfunctions

 Outline
This chapter describes the troubleshooting for this machine.
 Rough identification of the source of the trouble
At the beginning of troubleshooting, it is necessary to identify roughly which functions the trouble relates to.
Problems can be roughly classified into those that relate to the machine itself and those that involve the connection
between the machine and the host computer.
 Problems related to the machine
The cause of the trouble can be identified by executing appropriate functions or using test functions.
 Problems related to the connection with the host computer
Hardware: Broken wire or faulty contact of cables
Software: Transmission by improper application setting
The standard priority of this machine is the "Host".
Check the settings on the host computer to see if there is any improper parameter setting.
START
Precautions in maintenance
Is there error message?
No
Is the
trouble due to the ink
quality?
No
Rough identification of error source
Execute appropriate functions or use test
functions of this machine
Do the
above functions operate
normally?
Yes
Troubles on the host computer side
If this troubleshooting cannot correct the trouble, check to see if the same trouble occurs
with another host computer (if possible).
© 2014 MIMAKI ENGINEERING CO.,LTD.
F/W ver
Yes
See
"7.1.2 List of Error
Yes
See
"7.2 Detailed Methods of Coping with the
No
1.10
Remark
Messages".
Malfunctions".
Rev.
1.0
1
2
3
4
5
6
7
8
7.1.1
R.1.0
P.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jv300-160

Table of Contents