MAINTENANCE MANUAL > Adjustment Items > Adjustment Function > DROP.POS
Model
JV300-130/160
Issued 2014.05.30 Revised
4.2.3 DROP.POS
Forward adjustment
#PRINT ADJUST
SELECT
:SiDir
ReDir
BiDir
#PRINT ADJUST
SELECT :SiDir
#PRINT ADJUST
SiDir :PRINT
Pattern drawing
Magnify by a microscope, and
measure it in inside readings.
360Std
SiDir WF3
H1A-H2A : 0.0
-99.9~99.9
Return adjustment
#PRINT ADJUST
SELECT
:ReDir
SiDir
BiDir
#PRINT ADJUST
SELECT:ReDir
#PRINT ADJUST
ReDir:PRINT
Pattern drawing
360Std
ReDir WF3
H1A-H2A : 0.0
-99.9~99.9
© 2014 MIMAKI ENGINEERING CO.,LTD.
F/W ver.
1.00
5. Select "SiDir" on the [SELECT] display.
[] / [] : Switches
[ENTER] : Confirms (Next)
6. Press the [ENTER] key to draw the pattern.
[ENTER] : To start Pattern drawing
[] : To the compensation display
(Without drawing)
Adjust the followings for all.
WF3 : 540, 720, 1440 dpi
WF4 : 360, 540 dpi
7. Check and compensate the patterns.
Input the adjustment value (the measured value: μm) so that the
impact dots of the H2A line is at the same position in the Y-
direction, referring to the reference nozzle H1A line.
[] / [] : Compensating value input (Input unit:
[ENTER] : Confirms (Next)
Input the compensating value, referring to the left
figure, if the displacement on the drop position of
head applied for the compensation occurs either right
or left against the reference head.
8. When compensated, draw and check the patterns again.
Repeat "Drawing -> Checking (Compensating)" until
any compensation is not required.
9. On the [SELECT] display, select "ReDir", and adjust it in the
same way as "SiDir".
[] / [] : Switches
[ENTER] : Confirms (Next)
10. Press the [ENTER] key to draw the pattern.
[ENTER] : To start Pattern drawing
[] : To the compensation display
(Without drawing)
11. When compensated, draw and check the patterns again.
Repeat "Drawing -> Checking (Compensating)" until
any compensation is not required.
Remark
4.2.3
Rev.
1.0
1
2
3
20
µm)
4
5
6
7
8
P.2
R.1.0