Stagger Adjustment; Check The Stagger Of Each Column - MIMAKI JV300-130 Maintenance Manual

Hide thumbs Also See for JV300-130:
Table of Contents

Advertisement

MAINTENANCE MANUAL > Adjustment Items > Adjustment Function > AVERAGING 34 ADJUST
Model
JV300-130/160
Issued 2014.05.30 Revised
4.2.1 AVERAGING 34 ADJUST
 Stagger Adjustment
 It is necessary to perform SLANT adjustment before STAGGER adjustment.
 After adjusting the stagger, adjust the slant.
Stagger confirmation point
Columns "b"
Columns "a" Columns "b"Columns "a"
Effective
Width x dots
Used nozzle
4-color
M
M
C
C
Col. "a"
C
M
Col. "b"
<Scope Image>
Not effective
<Adjustment Example>
Columns "b"
© 2014 MIMAKI ENGINEERING CO.,LTD.
1. Carry out the slant adjustment through the following proce-
dures.
Patterns of columns "a" and columns "b" are printed alternately
(Refer to the left figure).
The magenta and cyan strips (indicated by the thick red arrows
in the diagram on the left) printed over the respective patterns at
Not effective
the top. These strips indicate that magenta is column "a" and
cyan is column "b".
Patterns of effective overlapping and not effective are printed
alternately (They are dotted line-form part on the middle of the
pattern).
6-color+W, 8-color
C
M
Lc
M
C
Lm
Effective
P
e
r
f
o
r
Columns "a"
m
a
n
a
v
e
r
a
g
i
n
g
a
d
j
u
s
t
m
e
n
t
.
F/W ver.
1.00
Remark
Overlap of dots between the heads is 16 dots.

Check the stagger of each column.

Adjust it so that 8 nozzles each for both edges of the head to
be adjusted may be overlapped in alignment in the X
direction.
Perform an averaging adjustment.
Adjust it so that 8 nozzles each for both edges of column "a"
and column "b" may be overlapped on average in the X
direction.
Rev.
1.0
1
2
3
4
5
6
7
8
4.2.1
R.1.0
P.4