Y Drive Pulley - MIMAKI JV300-130 Maintenance Manual

Hide thumbs Also See for JV300-130:
Table of Contents

Advertisement

MAINTENANCE MANUAL > Disassembly and Reassembly > Drive System > Y Drive Pulley
Model
JV300-130/160
Issued 2014.05.30 Revised

6.3.3 Y Drive Pulley

 Work procedures
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
Y-SP plate
Loosen
Workable from the
cover outside
© 2014 MIMAKI ENGINEERING CO.,LTD.
Y Drive Pulley
1. Remove the Cover R.
2. Manually move the print head carriage on the platen and
Y pulley cover
remove the Y-pulley cover.
3. Loosen the screws from the Y-SP plate on the left side of the
main body, and release the tension of the Y drive belt.
F/W ver
1.00
Remark
You can access a screw from hole of the cover L.
Rev.
1.0
1
2
3
4
5
6
7
8
6.3.3
R.1.0
P.1