6.2.12 Clamp Assy.

 Work procedures
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
© 2014 MIMAKI ENGINEERING CO.,LTD.
Clamp Assy. x20
Pinch roller
For replacement : SPA-0247 PR10
1. Turn off the main power supply of the machine.
2. Remove the Y cover 160.
3. Remove the Clamp hold plate A (2 range, screw x2) or Clamp
Clamp hold plate
hold plate (3 range, screw x3).
4. Remove the Clamp Assy.
Clamp Assy.
5. Reverse the disassembly procedure for reassembly.